TRV-2026-2311Version 1 · Certified
Reason for this version
Certified into the record
Canonical text (the exact bytes fingerprinted)
TRUVACE RECORD VERSION record: TRV-2026-2311 version: 1 kind: certified reason: Certified into the record timestamp: 2026-10-29T18:34:39.572902Z status: published lens: g_space sector: health headline: Artificial Intelligence Applied to Echocardiography for Detection of Heart Failure with Preserved Ejection Fraction and Elevated Filling Pressures: A Diagnostic Test Accuracy Meta-Analysis dek: Heart failure with preserved ejection fraction (HFpEF) accounts for nearly half of heart failure cases and remains difficult to diagnose non-invasively. Artificial intelligence (AI) applied to echocardiography may improve detection, but its aggregate diagnostic accuracy has not been quantified. We performed a diagnostic test accuracy meta-analysis of AI-enabled echocardiography for identifying HFpEF, elevated left ventricular filling pressure, or diastolic dysfunction. MEDLINE/PubMed, Embase, and CENTRAL were se… gain_title: Pooled across eight studies, AI applied to echocardiography detected HFpEF and elevated filling pressures with roughly 84% sensitivity and 83% specificity, offering a non-invasive route for a condition that is hard to diagnose. problem_title: (none) trace_subject: (none) gain_reading: Pooled across eight studies, AI applied to echocardiography detected HFpEF and elevated filling pressures with roughly 84% sensitivity and 83% specificity, offering a non-invasive route for a condition that is hard to diagnose. gain_evidence: Pooled sensitivity was 84.0% (95% CI: 73.0-91.0%) and specificity 83.0% (95% CI: 73.0-89.0%) | AI-enabled echocardiography shows good pooled accuracy for detecting HFpEF and elevated filling pressures problem_reading: (none) problem_evidence: (none) quick_read: Researchers pooled results from eight studies covering 2770 participants to measure how well AI models applied to echocardiograms identify heart failure with preserved ejection fraction, elevated left ventricular filling pressure, or diastolic dysfunction. Databases were searched through June 2026 and models were compared with invasive or guideline-based reference standards. The finding matters because HFpEF makes up nearly half of heart failure cases and is difficult to confirm without invasive testing. Yet the evidence base is small and inconsistent, so it remains unclear how the tools would perform in routine care across different reference standards and patient groups. limitation: Heterogeneity across the included studies was high and accuracy varied significantly by reference standard, so the authors call for larger, prospectively validated studies before routine clinical adoption. tag: Evidence-backed gain key_points: Eight studies with 2770 participants were included, and 1317 (47.5%) had the target condition. | The area under the summary ROC curve was 0.875, and the diagnostic odds ratio was 24.73. | Positive and negative likelihood ratios were 4.84 and 0.20. | Accuracy did not differ by AI architecture but varied significantly by reference standard. rundown: The team searched MEDLINE/PubMed, Embase, and CENTRAL from inception to June 2026 and included studies that tested AI models on echocardiography against invasive, guideline-adjudicated, or ASE/EACVI reference standards. Sensitivity and specificity were pooled with a bivariate random-effects model, and risk of bias was assessed with QUADAS-2. Beyond pooled sensitivity and specificity, the analysis reported a summary ROC area of 0.875 and a diagnostic odds ratio of 24.73. No small-study effects were detected, suggesting publication bias was not evident in this set. The authors conclude the results support diagnostic potential but call for larger, prospectively validated studies before routine clinical adoption, citing high heterogeneity and dependence on the reference standard. sources: - peer_reviewed | Cardiology in Review | https://doi.org/10.1097/crd.0000000000001523 | 2026-10-29 prev: 0000000000000000000000000000000000000000000000000000000000000000
- sha256
- 987f2dadb0f3983acd5f2f3cc0da26f893ea2e0b24107761138300981a9a2efb
- previous
- 0000000000000000000000000000000000000000000000000000000000000000
Verify this record
How to verify without trusting this page
Fetch the canonical text of any version from /api/record/TRV-2026-2311 and hash it yourself — for example shasum -a 256 on the saved canonical field. The result must equal content_hash, and each version’s text ends with prev:followed by the prior version’s hash (version 1 chains to 64 zeros). If a single character of any version had been altered since certification, the chain would not reproduce.
ace