TRV-2026-0902Version 3 · Revised

Saved · see the current record

Why this version exists

Voice pass: plainer wording and study attribution; no facts or figures changed.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0902
version: 3
kind: revised
reason: Voice pass: plainer wording and study attribution; no facts or figures changed.
timestamp: 2026-11-05T11:20:18.176763Z
status: published
lens: g_space
sector: health
headline: AI-ICE Guided Pulsed Field Ablation of Atrial Fibrillation with Variable Loop Circular Catheter
dek: Background Intracardiac echocardiography (ICE) facilitates left atrial (LA) reconstruction during atrial fibrillation (AF) ablation. The artificial intelligence-based CARTOSOUND FAM (AIFAM) module enables automated three-dimensional LA reconstruction without the need for a dedicated pre-ablation mapping catheter. While this workflow has been described previously in radiofrequency ablation, its application and outcome in pulsed field ablation (PFA) remains limited. Objective To evaluate the feasibility, safety, a…
gain_title: In an observational study of 210 atrial fibrillation patients, an AI-built left atrial map from ultrasound replaced a separate mapping catheter, and all pulmonary veins were isolated; 77.7% (paroxysmal) and 71.8% (non-paroxysmal) stayed arrhythmia-free at 270 days.
problem_title: (none)
trace_subject: (none)
gain_reading: In an observational study of 210 atrial fibrillation patients, an AI-built left atrial map from ultrasound replaced a separate mapping catheter, and all pulmonary veins were isolated; 77.7% (paroxysmal) and 71.8% (non-paroxysmal) stayed arrhythmia-free at 270 days.
gain_evidence: The artificial intelligence-based CARTOSOUND FAM (AIFAM) module enables automated three-dimensional LA reconstruction without the need for a dedicated pre-ablation mapping catheter. | Acute procedural success was achieved in 100% of cases. | freedom from arrhythmia survival after 60-day blanking was 77.7% in paroxysmal AF and 71.8% in non-paroxysmal AF at 270 days.
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers tested a no-pre-mapping workflow using the AI-based CARTOSOUND FAM module to build a three-dimensional left atrial shell from intracardiac echocardiography acquired in the right atrium, then used that shell alone to guide pulsed field ablation with a Variable Loop Circular Catheter. In 210 patients, including 76 with concomitant left atrial appendage occlusion, all pulmonary vein isolations were completed with frequent additional posterior wall and superior vena cava lesions.

The approach matters because it suggests AI reconstruction can replace a dedicated mapping catheter step while maintaining procedural efficiency and safety in a contemporary AF cohort. Uncertainty remains about generalizability beyond select index ablation cases, comparative effectiveness versus conventional mapping, and durability of arrhythmia control given incomplete follow-up and absence of a control arm.
limitation: Observational single-arm design limited to select patients undergoing index ablation with incomplete follow-up, as only 184 of 210 had at least one follow-up for arrhythmia assessment.
tag: Evidence-backed gain
key_points: Study evaluated AIFAM-guided workflow during PFA using Variable Loop Circular Catheter in 210 patients without pre-map out of 412 screened. | Mean age 68.1 years, 52% paroxysmal AF, 48% non-paroxysmal, mean CHA2DS2-VASc 3.4, with 36% undergoing concomitant AF ablation and left atrial appendage occlusion. | All patients had pulmonary vein isolation plus posterior wall isolation in 87.5% and superior vena cava ablation in 60.5%. | Skin-to-skin time 78.8 min and LA dwell 47.1 min for ablation alone, 87.3 min and 54.6 min for concomitant ablation and LAAO.
rundown: Investigators screened 412 patients undergoing AF ablation with VLCC and analyzed 210 who had AIFAM-guided ablation without pre-map. LA shell was created using the AI-based ICE module from the right atrium and used as the only reference shell for PFA delivery.

Acute procedural success was 100% with one acute non-catheter related vascular complication (0.5%) and no late complications documented. Follow-up in 184 patients showed Kaplan-Meier freedom from arrhythmia after 60-day blanking of 77.7% for paroxysmal and 71.8% for non-paroxysmal AF at 270 days.
sources:
- peer_reviewed | Europace | https://doi.org/10.1093/europace/euag212 | 2026-08-26
prev: 543c44b4cf53cfa53c0e74aa1ff9a3a90c194629a64ebb1d2c3d5f628ac7cd3d
SHA-256 hash
5a04521c939f131dca467bce254a02aeced67bc948488d8dfa1d8c091051a134
Previous version’s hash
543c44b4cf53cfa53c0e74aa1ff9a3a90c194629a64ebb1d2c3d5f628ac7cd3d
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0902 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.