Moderate evidenceWhy 60?
What kind of evidence this is, how big it was and how many independent sources back it.
- Observational study
- 60
- Evidence strength
- 60
Moderate from 50. High from 75, with at least two independent sources.
How it is scoredPublished recordHealthGood Space
More
AI-ICE Guided Pulsed Field Ablation of Atrial Fibrillation with Variable Loop Circular Catheter
- Truvace record
- TRV-2026-0902raw data (JSON)
- Version
- v3Revised
- First published
- Evidence type
- Observational study
- Sources
- 1 sourcePeer-reviewed
- sha256
- 5a04521c939f…check it
Background Intracardiac echocardiography (ICE) facilitates left atrial (LA) reconstruction during atrial fibrillation (AF) ablation. The artificial intelligence-based CARTOSOUND FAM (AIFAM) module enables automated three-dimensional LA reconstruction without the need for a dedicated pre-ablation mapping catheter. While this workflow has been described previously in radiofrequency ablation, its application and outcome in pulsed field ablation (PFA) remains limited. Objective To evaluate the feasibility, safety, a…
The gain
In an observational study of 210 atrial fibrillation patients, an AI-built left atrial map from ultrasound replaced a separate mapping catheter, and all pulmonary veins were isolated; 77.7% (paroxysmal) and 71.8% (non-paroxysmal) stayed arrhythmia-free at 270 days.
What this doesn’t fix
Observational single-arm design limited to select patients undergoing index ablation with incomplete follow-up, as only 184 of 210 had at least one follow-up for arrhythmia assessment.
Sources
1 on file- Europacedoi:10.1093/europace/euag212
Cite this record
v3Truvace Impact Record TRV-2026-0902, v3: “AI-ICE Guided Pulsed Field Ablation of Atrial Fibrillation with Variable Loop Circular Catheter.” Truvace, 2026-11-05. /record/TRV-2026-0902 (accessed on the day you copy it). sha256 5a04521c939f131d…
Change history
3 versionsEvery change made to this record since it was first published, and why.
Voice pass: plainer wording and study attribution; no facts or figures changed.
Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
Certified into the record
Check this record hasn’t been altered
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-0902 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.