Moderate evidenceWhy 70?
What kind of evidence this is, how big it was and how many independent sources back it.
- Controlled or validated comparison
- 68
- Large sample (n = 11,806)
- +5
- One independent source, so it stops at 70
- 70 max
- Evidence strength
- 70
Moderate from 50. High from 75, with at least two independent sources.
How it is scoredMore
AI spots image flaws in breast MRI scans with 0.91 to 0.95 accuracy score, but only in one dataset
Study title: Slice-Wise Quality Assessment of High b Value Breast DWI via Deep Learning-Based Artifact Detection
- Evidence type
- Controlled or validated comparison
- Sample
- n = 11,806
- Sources
- 1 sourcePeer-reviewed
- Published
- 1 min read
- Truvace record
- TRV-2026-1291cite or check it
Study title: Slice-Wise Quality Assessment of High b Value Breast DWI via Deep Learning-Based Artifact Detection
Researchers developed convolutional neural networks to automatically flag intensity artifacts on high b-value breast diffusion-weighted MRI. Using 11,806 slices from 156 exams, DenseNet121 distinguished hyper- and hypointense artifacts with AUROCs of 0.91 and 0.95 on binary tasks and weighted AUROCs of 0.84 and 0.90 on multiclass tasks.
Read the study abstract
Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast MRI. Therefore, DWI is increasingly being incorporated into breast MRI protocols to address some of the shortcomings of routine clinical breast MRI. However, especially high b value DWI can be prone to intensity artifacts that can affect diagnostic image assessment. To detect hyper- and hypointense artifacts on high b value DWI (b = 1500 s/mm2) using deep learning, employing either a binary classification (artifact prese…
The gain
In a retrospective study of 156 breast MRI exams, a DenseNet121 deep learning model detected bright and dark image artifacts on held-out slices with AUROCs of 0.91 and 0.95.
In brief
Reliable slice-wise quality assessment could help prevent artifact-related misinterpretation as DWI is added to breast MRI protocols to support lesion detection. The work remains retrospective and limited to one dataset, so prospective testing across scanners, protocols, and patient populations is needed to confirm generalizability and clinical impact.
Main points
- Retrospective study used 11,806 DWI slices from 156 examinations of female patients between 2022 and mid-2023 at 3T with b values 50, 750, and 1500 s/mm2.
- Three CNNs (DenseNet121, ResNet18, SEResNet50) were trained for binary artifact presence; best model DenseNet121 was tested on independent holdout sets of 1836 and 1822 slices.
- Multiclass classification yielded weighted AUROCs of 0.84 and 0.90, with Grad-CAM bounding boxes scored 3.52 ± 0.81 and 3.62 ± 0.65 on 5-point Likert-like scale by radiologist.
The full story
The team labeled slices for hyper- and hypointense artifacts and split them into training, validation, and holdout sets (8164/1806/1836 and 8164/1820/1822). They compared DenseNet121, ResNet18, and SEResNet50 for binary detection, then extended the best model to multiclass intensity classification.
Evaluation used accuracy, precision, recall, AUROC and AUPRC, plus radiologist review of Grad-CAM heatmap bounding boxes on 150 validation and 200 holdout slices. Results were reported on single-slice high b-value diffusion-weighted images at b = 1500 s/mm2.
Sources
1 on file- Journal of Magnetic Resonance Imagingdoi:10.1002/jmri.70572
Talk it over
The DenseNet121 model reached AUROCs of 0.91 and 0.95 on held-out slices from 156 breast MRI exams. What can a retrospective study from one dataset show about how it would work elsewhere?
AI spots image flaws in breast MRI scans with 0.91 to 0.95 accuracy score, but only in one datasethttps://truvace.com/item/slice-wise-quality-assessment-of-high-b-value-breast-dwi-via-deep-learning-based
The DenseNet121 model reached AUROCs of 0.91 and 0.95 on held-out slices from 156 breast MRI exams. What can a retrospective study from one dataset show about how it would work elsewhere?
Answer in the threadThe exams came from female patients scanned between 2022 and mid-2023 at 3T. Which scanners, protocols or patient groups missing from the data could change how well the model flags artifacts?
Answer in the threadA radiologist scored the Grad-CAM bounding boxes at 3.52 ± 0.81 and 3.62 ± 0.65 on a 5-point scale. What result in a prospective test would make you trust the model to flag slices in routine scans?
Answer in the thread
If you have more time
The model was tested on single-slice images at b = 1500 s/mm2. Who should decide whether a flagged slice is repeated, ignored or reviewed by a radiologist?
Answer in the threadLook up how prospective testing across scanners is usually done for imaging tools. What would you ask the researchers to report that the 1836 and 1822 slice holdout sets could not?
Answer in the thread
ace
What readers say