Moderate evidenceWhy 68?
What kind of evidence this is, how big it was and how many independent sources back it.
- Controlled or validated comparison
- 68
- Evidence strength
- 68
Moderate from 50. High from 75, with at least two independent sources.
How it is scoredMore
Gemini matched experts within 5° on 61.6% of spine X-rays, GPT-5.1 on 24.8%, a study found
Study title: Can General-purpose Multimodal AI Reliably Measure Cobb Angles? A Head-to-head Diagnostic Agreement Study of GPT-5.1 and Gemini 3.1 Pro in Adolescent Idiopathic Scoliosis
- Evidence type
- Controlled or validated comparison
- Sample
- n = 125
- Sources
- 1 sourcePeer-reviewed
- Published
- 1 min read
- Truvace record
- TRV-2026-1361cite or check it
Study title: Can General-purpose Multimodal AI Reliably Measure Cobb Angles? A Head-to-head Diagnostic Agreement Study of GPT-5.1 and Gemini 3.1 Pro in Adolescent Idiopathic Scoliosis
Researchers gave 125 anonymized standing whole-spine radiographs to GPT-5.1 and Gemini 3.1 Pro, each prompted once in a separate chat session, and compared their Cobb angle measurements with a joint expert-consensus reference. Gemini 3.1 Pro agreed with the reference more closely than GPT-5.1 on every main measure reported.
Read the study abstract
General-purpose multimodal artificial intelligence (AI) models can interpret radiographs through natural-language prompts, but their quantitative agreement and anatomical traceability in adolescent idiopathic scoliosis remain uncertain. We compared GPT-5.1 and Gemini 3.1 Pro with a joint expert-consensus reference on 125 anonymized standing coronal whole-spine radiographs. Each model evaluated each image once in an independent chat session using the same standardized prompt; only the first response was retained.…

The problem
On 125 spine X-rays, Gemini 3.1 Pro's Cobb angle error averaged 5.06° and GPT-5.1's 9.62° against expert consensus, and neither model identified end vertebrae reliably enough to measure curves autonomously.
In brief
The result matters because general-purpose chat models can read images from plain-language prompts, which could tempt clinical use in adolescent idiopathic scoliosis. Even the stronger model fell short of what autonomous measurement would need, and the study could not establish absolute accuracy or whether the models give repeatable answers.
Main points
- Gemini 3.1 Pro had an ICC of 0.842 versus 0.587 for GPT-5.1.
- Mean absolute error was 5.06° for Gemini versus 9.62° for GPT-5.1, and Gemini's mean bias was 3.46° versus 8.68°.
- Gemini placed 61.6% of measurements within 5° of the reference, versus 24.8% for GPT-5.1.
- Exact upper end-vertebra agreement was 14.4% versus 8.8%, and exact lower end-vertebra agreement was under 20% for both models.
The full story
The study used 125 anonymized standing coronal whole-spine radiographs. Each model evaluated each image once, using the same standardized prompt in an independent session, and only the first response was kept. Outcomes included intraclass correlation, mean absolute error, Bland-Altman analysis, error-threshold performance, categorical agreement, and end-vertebra concordance.
Categorical agreement favored Gemini 3.1 Pro: 80.0% versus 52.8% for angle-derived severity categories and 78.4% versus 52.8% for prompt-constrained management categories. Both differences were reported as paired P < 0.001.
The authors concluded that Gemini performed better under the tested single-session protocol but that neither model supported autonomous Cobb angle measurement, and that expert verification remains necessary.
Sources
1 on file- Journal of Imaging Informatics in Medicinedoi:10.1007/s10278-026-02394-0
Talk it over
Gemini 3.1 Pro placed 61.6% of measurements within 5° of the experts and GPT-5.1 placed 24.8%. How do you weigh the stronger model's result against the authors' view that neither could measure autonomously?
Gemini matched experts within 5° on 61.6% of spine X-rays, GPT-5.1 on 24.8%, a study foundhttps://truvace.com/item/can-general-purpose-multimodal-ai-reliably-measure-cobb-angles-a-head-to-head-di
Gemini 3.1 Pro placed 61.6% of measurements within 5° of the experts and GPT-5.1 placed 24.8%. How do you weigh the stronger model's result against the authors' view that neither could measure autonomously?
Answer in the threadEach model assessed each of the 125 radiographs once, in a single session, and only the first response was kept. How might the results change if each image had been run several times, and what would you want to see?
Answer in the threadIf you were one of the experts who set the joint reference for these X-rays, what would you want to see from a chat model before trusting its Cobb angle measurements?
Answer in the thread
If you have more time
Exact lower end-vertebra agreement was under 20% for both models. What would you ask a clinic about how it checks any AI measurement of a spine X-ray?
Answer in the threadThe study could not establish whether the models give repeatable answers. What kind of follow-up study, with which repeated prompts on the same radiographs, would settle that?
Answer in the thread
ace
What readers say