TRV-2026-3102Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-3102
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-23T12:02:05.379474Z
status: published
lens: g_space
sector: health
headline: Two-sample machine-learning estimation of rifampicin exposure in tuberculosis: an external validation study
dek: Objectives Subtherapeutic rifampicin exposure drives treatment failure and acquired resistance in tuberculosis. We aimed to develop and externally validate a concentration-driven machine learning (ML) model predicting rifampicin systemic exposure (AUC 0-24h ) from sparse clinical sampling, addressing the structural biases and limited generalizability of conventional Bayesian precision dosing. Methods Twenty-six published population pharmacokinetic models were benchmarked against real-world TDM data from a French…
gain_title: In an external validation study of 40 healthy volunteers and tuberculosis patients, a machine-learning model using blood samples at 2 and 8 hours put 75.0% of rifampicin exposure estimates within ±20% of reference values, versus 42.5% for dynamic model averaging.
problem_title: (none)
trace_subject: (none)
gain_reading: In an external validation study of 40 healthy volunteers and tuberculosis patients, a machine-learning model using blood samples at 2 and 8 hours put 75.0% of rifampicin exposure estimates within ±20% of reference values, versus 42.5% for dynamic model averaging.
gain_evidence: It achieved 75.0% of predictions within ±20% of the reference exposure, significantly outperforming the dynamic MA strategy (42.5%
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers built and externally validated an XGBoost machine-learning model that estimates how much rifampicin, a core tuberculosis drug, a patient is exposed to over 24 hours (AUC 0-24h) from just two blood samples taken 2 and 8 hours after a dose. Across the combined validation cohorts of 40 people, 75.0% of its predictions fell within ±20% of the reference exposure, against 42.5% for dynamic model averaging.

Low rifampicin exposure drives treatment failure and acquired drug resistance in tuberculosis. Conventional Bayesian precision dosing has structural biases and limited generalizability, so a covariate-free estimate from two samples could make therapeutic drug monitoring easier to scale.

The validation covered a US cohort of healthy volunteers and a Brazilian cohort of inpatients with tuberculosis, including HIV-coinfected patients. The authors say the results support further prospective assessment, not routine clinical use.
limitation: The validation cohorts totalled only 40 people, including healthy volunteers, and the authors say the approach still needs prospective assessment.
tag: Evidence-backed gain
key_points: The model predicts rifampicin AUC 0-24h from two plasma samples taken at 2 and 8 hours after the dose, which gave the best accuracy. | It was trained on 4,500 virtual patients simulated from five externally compatible population pharmacokinetic models. | Twenty-six published population pharmacokinetic models were first benchmarked against real-world monitoring data from a French cohort. | It was compared with Maximum A Posteriori Bayesian Estimation and dynamic Model Averaging. | External validation used two independent datasets: US healthy volunteers and Brazilian inpatients with tuberculosis, some HIV-coinfected. | In the combined cohorts (n = 40), 75.0% of predictions were within ±20% of reference exposure versus 42.5% for dynamic model averaging.
rundown: The team set out to fix limits of conventional Bayesian precision dosing for rifampicin, whose low exposure drives treatment failure and resistance. They benchmarked 26 published population pharmacokinetic models against therapeutic drug monitoring data from a French cohort and kept the five that were externally compatible.

Those five models simulated a training cohort of 4,500 virtual patients. An XGBoost regression model learned to predict 24-hour exposure from two-point sampling and was compared with Bayesian estimation (MAP-BE) and dynamic model averaging.

Testing used two fully independent datasets, a US cohort of healthy volunteers and a Brazilian cohort of inpatients with tuberculosis, including patients co-infected with HIV. The 2- and 8-hour sampling strategy gave the best accuracy, and the model was consistent across the 40 combined participants. The authors conclude the framework supports prospective assessment as a scalable decision-support approach for drug monitoring.
sources:
- peer_reviewed | Clinical Microbiology and Infection | https://doi.org/10.1016/j.cmi.2026.11.017 | 2026-11-20
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
ee05ea85ebd830208e0291a736b4a3308aded0813d82a3831f3f5fcf981401d8
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-3102 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.