Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-3091 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-22T00:02:35.778296Z status: published lens: g_space sector: health headline: Deep learning for predicting high-grade dysplasia in colorectal polyps using white-light endoscopy dek: BACKGROUND Accurate identification of high-grade dysplasia (HGD) in colorectal polyps is important for optimizing endoscopic management and surveillance strategies. Although deep learning has shown potential for colorectal polyp characterization, the generalizability of white-light imaging (WLI)-based models across independent clinical settings remains insufficiently established. AIM To develop and externally validate a deep learning model based on routine WLI images for predicting HGD in colorectal polyps, to e… gain_title: In a retrospective study at three Chinese hospitals, an AI model flagged high-grade dysplasia in colorectal polyp photos with AUCs of 0.814 and 0.803 in two outside cohorts, matching senior endoscopists and beating junior ones on 149 images. problem_title: (none) trace_subject: (none) gain_reading: In a retrospective study at three Chinese hospitals, an AI model flagged high-grade dysplasia in colorectal polyp photos with AUCs of 0.814 and 0.803 in two outside cohorts, matching senior endoscopists and beating junior ones on 149 images. gain_evidence: maintained consistent discrimination in two external validation cohorts problem_reading: (none) problem_evidence: (none) quick_read: Researchers at three tertiary hospitals in China built a MobileNetV2 deep learning model that predicts high-grade dysplasia in colorectal polyps from one routine white-light colonoscopy image per lesion. It scored an AUC of 0.879 on an internal test set of 146 polyps and 0.814 and 0.803 in two outside hospitals' cohorts of 159 and 182 polyps. In a blinded reader study of 149 images, two senior and two junior endoscopists made binary calls on the same pictures. The model performed within the range of the seniors and was more accurate overall than the juniors, which suggests it could support less experienced clinicians. A logistic regression model built from age, sex, lesion size, location and shape added no clear predictive value beyond the image-based prediction. The results are early. The outside cohorts held only 20 and 26 high-grade cases, so the estimates are imprecise, and positive predictive values were 34.1% and 39.6%. The model was tested on static, hand-picked images, not live colonoscopy, and the authors say prospective real-time validation is needed before any clinical use. limitation: The outside cohorts held only 20 and 26 high-grade cases, and the retrospective study used one hand-picked static image per polyp at three tertiary Chinese hospitals, so the model has not been tested in live colonoscopy. tag: Evidence-backed gain key_points: The internal test set of 146 polyps gave an AUC of 0.879 (95% CI 0.795-0.952), with 82.35% sensitivity and 82.17% specificity. | Outside cohort A (159 polyps, 20 high-grade) gave an AUC of 0.814 with 75.0% sensitivity and 79.1% specificity; cohort B (182 polyps, 26 high-grade) gave 0.803 with 80.8% and 79.5%. | Negative predictive value was 95.7% and 96.1% in the two outside cohorts, but positive predictive value was only 34.1% and 39.6%, meaning many false alarms. | In the reader study of 149 images (32 high-grade, 21.5%), the model performed within the range of two senior endoscopists and had higher overall accuracy than two junior endoscopists. | The model's five-class accuracy for polyp subtype was 52.1%, much weaker than its binary high-grade call. | A clinical model using age, sex, lesion size, location and shape added no clear value beyond the image model; age, size and distal location were still independently linked to high-grade dysplasia. | Calibration Brier scores were 0.092, 0.081 and 0.082 across the three cohorts, and subgroup AUCs by lesion size and location ranged from 0.74 to 0.88. rundown: The model was trained at the Second Hospital of Jilin University on 730 patients with confirmed polyps (79 with high-grade dysplasia, 10.8%) collected from January 2024 to January 2026, split 70/10/20 at the patient level. Two outside cohorts from Jilin Provincial People's Hospital and the First Affiliated Hospital of Jinzhou Medical University, collected June to December 2025, were not used for training, threshold setting or model selection. Each polyp contributed a single high-quality white-light image chosen by an experienced endoscopist, resized to 224 x 224 pixels. Pathology reports from each centre were the reference standard, and a central review of 149 cases agreed with the original diagnosis in 95.97% (143 of 149), with a kappa of 0.881. In the blinded reader study, four board-certified endoscopists (two with at least 10 years' experience and over 5,000 colonoscopies, two with under 3 years) judged the same 149 images as high-grade or not. Because they gave yes/no answers, the authors did not compare AUCs directly with the model, and they call the reader study exploratory. The authors list limitations: retrospective design with possible selection bias, few high-grade cases in the outside cohorts, validation only on white-light images, static images instead of real-time video, three tertiary Chinese hospitals only, and one image per lesion. They say the 0.2381 threshold may need local recalibration and that the findings do not establish readiness for clinical deployment. sources: - peer_reviewed | World Journal of Gastroenterology | https://doi.org/10.3748/wjg.125206 | 2027-01-21 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- d9eb385e820e54307cd4be3a7667f94bc15d9e586f5c268c793e6fa061cfe100
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-3091 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace