TRV-2026-3085Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-3085
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-21T00:02:18.287835Z
status: published
lens: g_space
sector: health
headline: Multicenter external validation of CT-based deep learning for proximal femoral fracture classification and quantitative fracture-line assessment
dek: To develop and externally validate a CT-based deep learning CAD system for proximal femoral fracture classification and fracture-line angle quantification and to preliminarily evaluate its clinical utility in a reader study. In this multicenter retrospective study, coronal CT images from four institutions were used for training (259 patients, 19,844 annotated images) and internal validation (91 patients, 92 hips). External validation included 200 patients from independent institutions scanned with CT systems fro…
gain_title: In a multicenter study with 200 externally validated patients, a CT deep learning system classified proximal femoral fractures with 91.5% accuracy, and residents' sensitivity for non-displaced femoral neck fractures rose from 0.47 to 0.78 with its help.
problem_title: (none)
trace_subject: (none)
gain_reading: In a multicenter study with 200 externally validated patients, a CT deep learning system classified proximal femoral fractures with 91.5% accuracy, and residents' sensitivity for non-displaced femoral neck fractures rose from 0.47 to 0.78 with its help.
gain_evidence: Overall classification accuracy was 95.7% (κ = 0.944) internally and 91.5% (κ = 0.887) externally | residents showed higher sensitivity with CAD assistance for non-displaced femoral neck fractures (0.78 vs. 0.47)
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers built a deep learning system that reads coronal CT images to classify proximal femoral (upper thigh bone) fractures. It reached 95.7% accuracy on internal validation and 91.5% on 200 patients from independent institutions.

The system also measured the fracture-line angle with a mean absolute error of 6.26° externally, close to the 5.18° difference seen between orthopedic specialists. In an exploratory six-reader study, residents detected more non-displaced femoral neck fractures with the tool's help, with sensitivity rising from 0.47 to 0.78.

Performance dropped outside the development hospitals, and F1-scores for some fracture categories fell as low as 0.667 externally. The reader study was exploratory, so the clinical benefit is preliminary.
limitation: Performance was lower on external data than internal data, and the six-reader study was exploratory and preliminary, so the clinical benefit is not yet established.
tag: Evidence-backed gain
key_points: Training used 259 patients and 19,844 annotated coronal CT images from four institutions; internal validation used 91 patients (92 hips). | External validation covered 200 patients from independent institutions scanned on CT systems from two vendors. | Classification accuracy was 95.7% (κ = 0.944) internally and 91.5% (κ = 0.887) externally. | F1-score ranges were 0.927-0.982 internally and 0.667-0.952 externally. | Fracture-line angle errors were 4.54° and 6.26°, versus 3.64° and 5.18° between orthopedic specialists. | Six readers took part in an exploratory study; residents' sensitivity for non-displaced femoral neck fractures rose from 0.47 to 0.78 with high specificity.
rundown: The study was retrospective and multicenter. It used a ResNet-50-based convolutional neural network to segment fracture regions, classify fractures, detect pelvic fractures and estimate the fracture-line angle on coronal CT images.

Agreement on fracture-line angles was moderate to good, with intraclass correlation coefficients of 0.817 internally and 0.736 externally. The angle errors approached the variation between orthopedic specialists.

The authors conclude the approach could support diagnosis and preoperative assessment of proximal femoral fractures. The reader study involved six readers and was described as exploratory.
sources:
- peer_reviewed | Skeletal Radiology | https://doi.org/10.1007/s00256-026-05447-1 | 2026-11-20
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
4df87eab04fac5be0eff7489b992ba340c8f9cda6af7834c854e19e26ad1f7bc
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-3085 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.