TRV-2026-3082Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-3082
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-20T18:02:49.237225Z
status: published
lens: g_space
sector: health
headline: Retrieval-augmented generation models for predicting pathological upgrading in endoscopically resected gastric low-grade intraepithelial neoplasia: A dual-center evaluation
dek: BACKGROUND Gastric low-grade intraepithelial neoplasia (LGIN) exhibits highly variable clinical outcomes. The discordance between histological findings from endoscopic forceps biopsy and endoscopic submucosal dissection (ESD) complicates the formulation of appropriate treatment strategies. AIM To evaluate a prediction framework using large language models (LLMs) enhanced with retrieval-augmented generation (RAG) for the pathological upgrading of gastric LGIN. METHODS We retrospectively enrolled 329 patients with…
gain_title: In a retrospective study of 329 patients with 372 gastric lesions, AI language models given a literature knowledge base predicted which low-grade lesions were upgraded after removal with an AUC of 0.873, comparable to two experienced endoscopists.
problem_title: (none)
trace_subject: (none)
gain_reading: In a retrospective study of 329 patients with 372 gastric lesions, AI language models given a literature knowledge base predicted which low-grade lesions were upgraded after removal with an AUC of 0.873, comparable to two experienced endoscopists.
gain_evidence: demonstrating performance comparable to that of experienced endoscopists and baseline model
problem_reading: (none)
problem_evidence: (none)
quick_read: A retrospective study at two tertiary hospitals tested whether AI language models could predict which gastric low-grade intraepithelial neoplasia lesions would turn out to be high-grade neoplasia or early gastric cancer after endoscopic removal. It covered 329 patients with 372 lesions, and 148 lesions (40%) were upgraded.

The retrieval-augmented DeepSeek-V3 scored an AUC of 0.873 and Qwen3-235b 0.862. Neither differed significantly from two experienced endoscopists or a generalized linear mixed model baseline. Biopsy and removal results often disagree, which complicates treatment choices, so a tool that flags likely upgrades could inform decisions about removal.

The work is retrospective and the authors say the models need prospective validation before they can support clinical decisions.
limitation: The study was retrospective, and the authors say the models may support clinical decision-making only pending prospective validation.
tag: Evidence-backed gain
key_points: The study enrolled 329 patients with 372 gastric lesions from two tertiary hospitals; all had a biopsy diagnosis of low-grade neoplasia before endoscopic submucosal dissection. | 148 lesions (40%) were upgraded to high-grade intraepithelial neoplasia or early gastric cancer. | RAG-enhanced DeepSeek-V3 reached an AUC of 0.873 (95% CI 0.828-0.901); Qwen3-235b reached 0.862 (95% CI 0.818-0.893). | DeepSeek-V3 had 85.1% sensitivity, 80.4% specificity, 74.1% positive and 89.1% negative predictive value at a 0.357 threshold. | Qwen3-235b had 84.5% sensitivity, 77.2% specificity, 71.0% positive and 88.3% negative predictive value at a 0.453 threshold. | Decision curve analysis showed clinical utility across threshold probabilities of 15%-80%, and accuracy held up in lesions measuring 1-2 cm.
rundown: The researchers built a knowledge base from 28 peer-reviewed articles on how low-grade lesions get upgraded. Two language models, DeepSeek-V3 and Qwen3-235b, used it in a zero-shot setting to produce an upgrade probability and a reasoning report for each lesion.

Performance was judged by AUC, calibration plots and decision curve analysis, and compared with a generalized linear mixed model baseline and two experienced endoscopists. DeLong tests found no significant differences from the endoscopists or the baseline (P > 0.05).

At thresholds picked by the maximum Youden index, both models caught about 85% of upgraded lesions. Their negative predictive values were 89.1% and 88.3%. The authors conclude the models may support decisions about endoscopic removal, pending prospective validation.
sources:
- peer_reviewed | World Journal of Gastroenterology | https://doi.org/10.3748/wjg.122422 | 2027-01-07
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
a6b35bae2659c6d19f7c2fbf6acee18ee68767635139926e8c3479e35f45c634
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-3082 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.