Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-3047 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-19T06:03:38.010932Z status: published lens: g_space sector: health headline: DIAGNOSTIC ACCURACY OF ARTIFICIAL INTELLIGENCEBASED SYSTEMS FOR DETECTION OF DENTAL CARIES COMPARED WITH CONVENTIONAL DIAGNOSTIC METHODS dek: Objective: To evaluate the diagnostic accuracy of an artificial intelligence (AI)-based dental caries detection system compared with conventional clinical and radiographic diagnostic methods in patients presenting for routine dental examination. Methods: This comparative diagnostic accuracy study included 210 patients undergoing dental examination. Each participant received a standardized clinical examination followed by digital intraoral bitewing radiography when indicated. Dental caries were assessed using con… gain_title: In a 210-patient study at a Pakistani dental college, an AI caries detector had 91.5% sensitivity, versus 82.2% for dentists' clinical examination and 87.3% for their radiograph reading. problem_title: (none) trace_subject: (none) gain_reading: In a 210-patient study at a Pakistani dental college, an AI caries detector had 91.5% sensitivity, versus 82.2% for dentists' clinical examination and 87.3% for their radiograph reading. gain_evidence: The AUC was 0.934 for AI, compared with 0.846 for conventional clinical examination and 0.882 for radiographic interpretation. problem_reading: (none) problem_evidence: (none) quick_read: A comparative diagnostic accuracy study of 210 adults at Shahida Islam Dental College in Lodhran, Pakistan, tested a deep-learning caries detector on bitewing radiographs. It reached 90.9% overall accuracy, with 91.5% sensitivity and 90.2% specificity, against a consensus reference diagnosis by two clinicians. Dentists' visual-tactile examination reached 84.3% accuracy (82.2% sensitivity) and their reading of the radiographs 88.1% (87.3% sensitivity). The AI's area under the curve was 0.934, versus 0.846 for clinical examination and 0.882 for radiographic interpretation. The gap narrows against combined conventional assessment, which scored 89.3% accuracy and an AUC of 0.908. The AI was weakest on early enamel lesions, where sensitivity was 78.4%, and the authors say it should support dentists rather than replace them until tested in larger multicentre groups. limitation: The authors list a modest sample size from one college and no assessment of long-term treatment outcomes, and say the AI should complement dentists until validated in larger multicentre studies. tag: Evidence-backed gain key_points: The study enrolled 210 consecutive adults (126 men, 84 women, mean age 34.8) attending routine dental assessment; 118 (56.2%) had caries by the reference standard. | The AI system scored 91.5% sensitivity, 90.2% specificity, 91.5% PPV, 90.2% NPV and 90.9% accuracy. | Clinical examination scored 82.2% sensitivity, 86.9% specificity and 84.3% accuracy; radiographic interpretation scored 87.3%, 89.1% and 88.1%. | Combined conventional assessment reached 89.0% sensitivity, 89.6% specificity and 89.3% accuracy, close to the AI result. | AUC was 0.934 (95% CI 0.901–0.967) for AI, 0.908 for combined conventional assessment, 0.882 for radiographs and 0.846 for clinical examination. | AI sensitivity rose with lesion depth: 78.4% for early enamel, 89.7% for established enamel/proximal, 93.5% for early dentinal and 97.1% for advanced dentinal lesions. | Specificity stayed between 90.6% and 92.4% across lesion categories. rundown: Each participant had a standardized mirror-and-probe examination under adequate illumination, followed by digital intraoral bitewing radiography when indicated. Experienced dentists read the radiographs while blinded to the AI output, and the same images were run through the deep-learning system, which labelled each surface caries-positive or caries-negative. The reference standard was a consensus diagnosis by two experienced dental clinicians, with a senior oral and maxillofacial radiologist adjudicating disagreements. Patients with extensive restorations obscuring surfaces, severe developmental abnormalities, non-diagnostic radiographs or incomplete records were excluded. Clinical examination missed the most cases. The AI's sensitivity was 91.5% against 82.2% for clinical examination and 87.3% for radiographic reading. Its advantage over the combined conventional approach was smaller, at 90.9% versus 89.3% accuracy. Performance depended on lesion depth. For early enamel lesions the AI had 78.4% sensitivity and 86.7% accuracy; for advanced dentinal lesions it reached 97.1% sensitivity and 94.8% accuracy. The authors say subtle early demineralization remains a diagnostic challenge. sources: - peer_reviewed | International Journal of Drug Delivery Technology | https://doi.org/10.25258/ijddt.16.80s.130 | 2026-11-17 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- 5bb1e250c12dd4f179d30cea6405c407a7403613d3ad6ed3ca49f98158c4417e
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-3047 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace