TRV-2026-2967Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-2967
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-16T12:02:31.167785Z
status: published
lens: p_space
sector: health
headline: Large language models for orthodontic classification using intraoral digital models: a diagnostic accuracy and reproducibility study
dek: Abstract Background Multimodal artificial intelligence (AI) systems built on large language models are consulted by patients and clinicians, but their performance on visual orthodontic classification is not well characterized. This study evaluated three such systems for agreement with an expert orthodontist reference standard, category-specific diagnostic performance and four-week reproducibility, using intraoral digital scan exports. Methods In this retrospective diagnostic accuracy study, 90 patients were sele…
gain_title: (none)
problem_title: In a retrospective study of 90 patients' intraoral scans, Claude Opus 4.7, GPT-5.5 and Gemini 3 Flash agreed poorly with orthodontists (kappa up to 0.299) and detected only 10.0–13.3% of Class III cases versus 60.0–80.0% of Class I.
trace_subject: (none)
gain_reading: (none)
gain_evidence: (none)
problem_reading: In a retrospective study of 90 patients' intraoral scans, Claude Opus 4.7, GPT-5.5 and Gemini 3 Flash agreed poorly with orthodontists (kappa up to 0.299) and detected only 10.0–13.3% of Class III cases versus 60.0–80.0% of Class I.
problem_evidence: Class III sensitivity was 10.0–13.3%, compared with 60.0–80.0% for Class I.
quick_read: A retrospective diagnostic accuracy study tested Claude Opus 4.7, GPT-5.5 and Gemini 3 Flash on archived iTero intraoral scans from 90 patients, 30 in each Angle class. Overall accuracy ranged from 29.2% (Gemini 3 Flash, arch form) to 64.0% (GPT-5.5, arch form), and kappa agreement with the expert reference never exceeded 0.299.

The chatbots were weakest on Class III malocclusion, where sensitivity was 10.0–13.3% against 60.0–80.0% for Class I. The authors conclude that overall accuracy hid this category-level weakness and that the systems are not suitable for standalone orthodontic diagnosis under the conditions tested.

Results were also unstable over time. When 20 patients were reassessed after four weeks, sagittal accuracy fell from 55.0–60.0% to 5.0–35.0%, and most test-retest kappa confidence intervals included zero.
limitation: The findings apply only to the conditions tested: three named chatbots, one zero-shot prompt, five two-dimensional views, and a retest of only 20 patients.
tag: Evidence-backed problem
key_points: The study used 90 archived patient records, with 30 patients in each Angle class. | Five standardized two-dimensional views from each iTero scan were given to each chatbot with a single zero-shot prompt. | Two orthodontists classified each case from the complete scan record with metric measurements; their agreed categories formed the reference standard. | Macro-average recall ranged from 38.7% (Gemini 3 Flash, arch form) to 60.9% (GPT-5.5, vertical relationship). | Class III sensitivity was 10.0–13.3%, compared with 60.0–80.0% for Class I. | Test-retest kappa ranged from −0.238 (Gemini 3 Flash, sagittal classification) to 0.433 (GPT-5.5, vertical relationship). | Classifying the same five images, the orthodontists agreed with the reference standard in 96.6–100% of cases.
rundown: Researchers assessed four parameters: sagittal classification, vertical relationship, crowding severity and arch form. Accuracy, class-specific sensitivity and specificity, macro-average recall and Cohen's kappa were calculated with 95% confidence intervals.

To check whether the images themselves were the problem, the orthodontists also classified all cases from the same five images. They agreed with the reference standard in 96.6–100% of cases, and each reproduced at least 19 of 20 classifications for each parameter at retest.

The chatbots did not hold steady over time. In the 20-patient retest after four weeks, sagittal accuracy fell from 55.0–60.0% to 5.0–35.0%, and most test-retest kappa intervals included zero. The authors say reproducibility must be evaluated separately from accuracy.
sources:
- peer_reviewed | BMC Oral Health | https://doi.org/10.1186/s12903-026-10465-5 | 2026-11-14
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
77889a1bdea1e45aedb1df8134daf0a6524389a6611c9ff39d70ddd8748d8585
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-2967 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.