Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-2966 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-16T12:02:19.958738Z status: published lens: g_space sector: health headline: Beyond chronological age: uncovering disease-dependent variability in AI-driven pediatric bone age assessment dek: Objectives To assess performance and agreement of a commercial artificial intelligence (AI) tool relative to routine pediatric radiologists' bone age assessments in a large pediatric cohort, with focus on different groups of growth disorders. Materials and methods One thousand five hundred sixteen anterior-posterior hand radiographs of pediatric patients (50.6% boys, mean age 10.84 ± 3.66 years) were retrospectively analyzed using the AI tool BoneAge. AI results were compared with board-certified pediatric radio… gain_title: In a retrospective study of 1,516 children's hand X-rays, the BoneAge AI tool differed from pediatric radiologists' bone age readings by a mean of 6.4 months, with correlation of 0.980 and intraclass correlation above 0.9. problem_title: (none) trace_subject: (none) gain_reading: In a retrospective study of 1,516 children's hand X-rays, the BoneAge AI tool differed from pediatric radiologists' bone age readings by a mean of 6.4 months, with correlation of 0.980 and intraclass correlation above 0.9. gain_evidence: Mean absolute difference (MAD) in estimated bone age by radiologists and AI was 6.4 ± 7.0 months for the whole cohort | There was significant correlation between AI and radiologists for the whole study population (ρ = 0.980) | ICCs for the entire cohort and the main indication groups were > 0.9 problem_reading: (none) problem_evidence: (none) quick_read: A retrospective study in Insights into Imaging compared the commercial BoneAge AI tool with routine bone age reports by board-certified pediatric radiologists on 1,516 hand radiographs. The children had a mean age of 10.84 years, and 50.6% were boys. The mean absolute difference between AI and radiologists was 6.4 months, and the two gave exactly the same result in 45.1% of cases. Correlation across the whole cohort was 0.980, and intraclass correlation exceeded 0.9. Agreement varied by the reason for imaging. Orthopedic cases matched best, with a mean difference of 4.1 months, while genetic/neuroendocrine cases differed by 6.6 months and oncologic cases by 6.7 months. The authors say radiologists should keep disease-specific differences in mind when using automated tools. limitation: The study was retrospective and compared the AI with radiologists' routine reports, and the orthopedic (n = 152) and oncologic (n = 185) subgroups were small relative to the genetic/neuroendocrine group (n = 1,179). tag: Evidence-backed gain key_points: The study analysed 1,516 anterior-posterior hand radiographs of children (mean age 10.84 ± 3.66 years; 50.6% boys). | AI output was compared with pediatric radiologists' reports using Bland-Altman plots, Spearman correlations and intraclass correlation coefficients. | Mean absolute difference was 6.4 ± 7.0 months, with complete concordance in 45.1% of cases. | Orthopedic cases (n = 152) had the smallest difference, 4.1 ± 5.6 months. | Genetic/neuroendocrine cases (n = 1,179) differed by 6.6 ± 7.2 months and oncologic cases (n = 185) by 6.7 ± 6.3 months. | Spearman correlations were 0.974 for genetic/neuroendocrine, 0.952 for orthopedic and 0.988 for oncologic indications. rundown: The researchers retrospectively analysed routine hand radiographs, setting the BoneAge software's estimates against reports already written by board-certified pediatric radiologists. This makes the comparison a real-world one rather than a test on a curated benchmark dataset. Across all 1,516 children, agreement was high: Spearman correlation was 0.980 and intraclass correlation exceeded 0.9 for the whole cohort and each indication group. The average gap was 6.4 months, and the AI and radiologists gave identical results in 45.1% of cases. Subgroup results differed. Orthopedic cases had the smallest gap (4.1 months), while the genetic/neuroendocrine group, the largest at 1,179 children, and the oncologic group had gaps near 6.6 and 6.7 months. The authors say this is the first study of this tool to consider the indication for imaging, and that radiologists should account for disease-specific differences when using automated tools. sources: - peer_reviewed | Insights into Imaging | https://doi.org/10.1186/s13244-026-02477-0 | 2026-11-14 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- 0a41c1c522a0fc9c0ed7794cf58db8ecb36d5f2b87b0ea0287cd5605f7c71547
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-2966 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace