Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-2954 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-16T00:03:15.147893Z status: published lens: g_space sector: health headline: Development of a Multimodal Model Combining Imaging and Clinical Data to Predict Bone Cement Leakage During Vertebroplasty for Fresh Thoracolumbar Compression Fractures dek: Background: Bone cement leakage is a common complication of percutaneous vertebroplasty (PVP), but perioperative risk stratification remains challenging. Existing models based on single-source clinical or imaging features have limited performance. This study aimed to develop and validate multimodal artificial intelligence (AI) models integrating clinical, imaging, and radiomics features to predict bone cement leakage during PVP. Methods: This multicenter study included 486 treated vertebrae from 378 patients at… gain_title: In a study of 486 treated vertebrae from 378 patients, multimodal AI models predicted cement leakage during vertebroplasty with AUCs of 0.902-0.939 on internal testing and 0.834-0.925 in a prospective cohort, above single-source models. problem_title: (none) trace_subject: (none) gain_reading: In a study of 486 treated vertebrae from 378 patients, multimodal AI models predicted cement leakage during vertebroplasty with AUCs of 0.902-0.939 on internal testing and 0.834-0.925 in a prospective cohort, above single-source models. gain_evidence: AUCs of 0.902-0.939 in the internal test cohort, 0.722-0.929 in the external validation cohort, and 0.834-0.925 in the prospective validation cohort problem_reading: (none) problem_evidence: (none) quick_read: A hospital team in China built machine-learning models to predict whether bone cement would leak outside the vertebra during percutaneous vertebroplasty, a common spine fracture treatment. Using 486 treated vertebrae from 378 patients, they combined clinical data, CT imaging findings and radiomics features. Multimodal models reached AUCs of 0.902-0.939 on the internal test set. Cement leakage occurred in 215 vertebrae (44.2%) and can cause serious problems such as neurological injury and pulmonary embolism. The models were also tested on 50 vertebrae from another hospital and 60 vertebrae from 50 prospectively enrolled patients, where AUCs ranged from 0.722-0.929 and 0.834-0.925. The models predict leakage seen on postoperative imaging, not symptoms or complications. The authors say larger and more diverse populations are needed before wider clinical use, and that any injection-technique changes based on predicted risk need prospective validation. limitation: CT scans came from different scanners and protocols, the models predict radiographic rather than symptomatic leakage, the external and prospective cohorts were small, and the authors say further evaluation in larger and more diverse populations is required. tag: Evidence-backed gain key_points: Leakage appeared in 215 of 486 treated vertebrae (44.2%) from 378 patients treated between January 2018 and June 2025 at three campuses of one hospital. | Higher BMI (OR 1.11), larger cement volume (OR 6.18), cortical destruction (OR 6.39) and posterior wall involvement (OR 8.05) were independent risk factors. | In the internal test set, the best single-modality models reached AUCs of 0.871 (clinical), 0.844 (imaging) and 0.806 (radiomics), versus 0.902-0.939 for multimodal models. | XGBoost scored highest in internal (0.939) and external (0.929) validation; random forest scored highest in the prospective cohort (0.925). | After Bonferroni correction, multimodal models beat their single-modality counterparts significantly in seven comparisons. | SHAP analysis ranked cortical destruction, cement injection volume and posterior wall involvement as the most influential predictors. | Removing three scanner-sensitive radiomics features lowered the SVM AUC by 0.022 to 0.036 across cohorts. rundown: The retrospective development cohort split into 385 training vertebrae from 301 patients and 101 test vertebrae from 77 patients, with all vertebrae from one patient kept in the same partition. Leakage was judged on postoperative imaging by three spine surgeons and two musculoskeletal radiologists. Six algorithms were used to build clinical, imaging, radiomics and multimodal models. In the internal test set, multimodal AUCs ranged from 0.902 to 0.939. In the external cohort of 50 vertebrae from 45 patients they ranged from 0.722 to 0.929, and in the prospective cohort of 60 vertebrae from 50 patients from 0.834 to 0.925. Patient-level aggregation gave AUCs of 0.865-0.912, and a test retaining one vertebra per patient gave mean AUCs of 0.889-0.918. A separate analysis of 108 locked model configurations gave median AUCs of 0.899 internally, 0.919 externally and 0.860 prospectively. Decision curve analysis showed net benefit at threshold probabilities of roughly 0.10-0.60. The authors suggest high predicted risk could prompt slower injection or tighter cement volume control, but say this needs prospective validation. sources: - peer_reviewed | JOR SPINE | https://doi.org/10.1002/jsp2.70227 | 2026-11-08 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- cf890418579f9bfdd0daca9bcaa6b162ae635301724cb781de65a7e5df56ac24
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-2954 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace