Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-2952 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-16T00:03:08.987050Z status: published lens: p_space sector: health headline: Diagnostic performance of S-detect artificial intelligence compared with conventional breast ultrasound for lesion characterization: a prospective lesion-based study dek: Abstract Purpose The aim of this prospective study was to compare the diagnostic performance of conventional breast ultrasound (US) assessment with S-Detect artificial intelligence (AI) for differentiating benign from malignant breast lesions. The study was not designed to assess reduction in biopsy rates. Materials and Methods A total of 130 women with 130 target breast lesions were prospectively evaluated from January 2024 to December 2025. One target lesion was analyzed per patient. Each lesion underwent conv… gain_title: (none) problem_title: In a prospective study of 130 women with breast lesions, the S-Detect AI tool had 63.3% specificity and 67.7% accuracy versus 87.2% and 87.7% for conventional ultrasound, with 40 false positives against 14. trace_subject: (none) gain_reading: (none) gain_evidence: (none) problem_reading: In a prospective study of 130 women with breast lesions, the S-Detect AI tool had 63.3% specificity and 67.7% accuracy versus 87.2% and 87.7% for conventional ultrasound, with 40 false positives against 14. problem_evidence: S-Detect showed the same sensitivity (90.5%) but lower specificity (63.3%), PPV (32.2%), and accuracy (67.7%) | S-Detect produced 40 false-positive results compared with 14 for conventional US quick_read: A prospective study of 130 women with 130 target breast lesions compared the S-Detect AI tool with conventional breast ultrasound. Histopathology found 109 benign lesions and 21 malignant ones. Both methods had 90.5% sensitivity, but S-Detect's specificity was 63.3% against 87.2% for conventional ultrasound. S-Detect produced 40 false-positive results compared with 14 for conventional ultrasound, and its accuracy was 67.7% versus 87.7%. A paired comparison showed it generated significantly more positive classifications (McNemar P < 0.001). The authors say the findings do not show a reduction in unnecessary biopsies, although the study was not designed to measure biopsy rates. They suggest S-Detect could serve as an adjunct to conventional assessment, with its clinical role needing larger prospective reader studies. limitation: The study was not designed to assess reduction in biopsy rates, and only 21 of the 130 lesions were malignant; the authors say larger prospective reader studies with predefined management rules are needed. tag: Evidence-backed problem key_points: The study enrolled 130 women between January 2024 and December 2025, analysing one target lesion per patient. | Histopathology was the reference standard: 109 lesions (83.9%) were benign and 21 (16.1%) malignant. | Conventional ultrasound with BI-RADS assessment had 90.5% sensitivity, 87.2% specificity, 57.6% PPV and 97.9% NPV. | S-Detect matched the 90.5% sensitivity but had 32.2% PPV and 97.2% NPV. | S-Detect gave 40 false positives versus 14 for conventional ultrasound. rundown: Each lesion received conventional B-mode ultrasound with a final BI-RADS assessment and an S-Detect analysis, and histopathology served as the reference. Sensitivity, specificity, PPV, NPV and accuracy were calculated with 95% confidence intervals. S-Detect's positive predictive value was 32.2% versus 57.6% for conventional ultrasound, and its accuracy was 67.7% versus 87.7%. Negative predictive value was similar at 97.2% and 97.9%. The authors conclude S-Detect may be used as an adjunct to conventional assessment, but its clinical role needs evaluation in larger prospective reader studies using predefined management rules. sources: - peer_reviewed | Egyptian Journal of Radiology and Nuclear Medicine | https://doi.org/10.1186/s43055-026-01910-0 | 2026-11-14 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- 797661fc7d36f14793566ad21d1fd9ea0acb6edf8bf6ee45449506291828fe15
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-2952 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace