TRV-2026-2942Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-2942
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-15T18:01:49.990392Z
status: published
lens: g_space
sector: health
headline: Diagnostic accuracy and reliability of susceptibility map-weighted imaging in patients with clinically uncertain parkinsonian syndromes
dek: Parkinson's disease (PD) is characterized by degeneration of dopaminergic neurons in the substantia nigra, accompanied by increased iron accumulation, particularly in the nigrosome-1 subregion. Differentiating neurodegenerative disorders like PD from non-neurodegenerative causes of parkinsonism can be challenging. In clinically uncertain parkinsonian syndrome (CUPS), dopamine transporter (DAT)-single-photon emission computed tomography (SPECT) can aid diagnosis. However, susceptibility map-weighted imaging (SMWI…
gain_title: In a study of 180 patients with clinically uncertain parkinsonism, four radiologists reading susceptibility MRI scans with AI software rose from 80% to 87% mean diagnostic accuracy, and agreement among them rose from a Fleiss κ of 0.65 to 0.86.
problem_title: (none)
trace_subject: (none)
gain_reading: In a study of 180 patients with clinically uncertain parkinsonism, four radiologists reading susceptibility MRI scans with AI software rose from 80% to 87% mean diagnostic accuracy, and agreement among them rose from a Fleiss κ of 0.65 to 0.86.
gain_evidence: With software assistance, diagnostic accuracy improved to 87% (range 85-91%), and inter-rater agreement increased to almost perfect (Fleiss κ 0.86). | Mean diagnostic accuracy was 80% (range 73-83%), with substantial inter-rater reliability (Fleiss κ 0.65).
problem_reading: (none)
problem_evidence: (none)
quick_read: A study of 180 patients with clinically uncertain parkinsonian syndrome tested whether AI-driven software could help radiologists read susceptibility map-weighted MRI scans. Radiologists alone reached a mean accuracy of 80%; with the software, that rose to 87%.

Agreement between the four radiologists also improved, from substantial (Fleiss κ 0.65) to almost perfect (0.86). The aim was to separate neurodegenerative parkinsonism from non-neurodegenerative causes, a distinction that is hard to make from symptoms alone.

The authors describe the MRI technique as an accessible alternative to dopamine transporter SPECT imaging, which is the usual aid in uncertain cases. The accuracy was measured against a final clinical diagnosis that included SPECT results.
limitation: 
tag: Evidence-backed gain
key_points: The study included 180 patients with clinically uncertain parkinsonian syndrome who had DAT-SPECT between January 2019 and July 2023. | Of the patients, 84 had neurodegenerative and 96 had non-neurodegenerative parkinsonism; mean age was 67.9 and 120 were male. | Four radiologists, blinded to symptoms and diagnosis, rated the nigrosome-1 region as normal, unclear or abnormal. | Unaided, mean diagnostic accuracy was 80%, with individual radiologists ranging from 73% to 83%. | With AI software, accuracy rose to 87%, with individual radiologists ranging from 85% to 91%. | Inter-rater agreement increased from a Fleiss κ of 0.65 to 0.86 with the software.
rundown: Parkinson's disease involves loss of dopaminergic neurons in the substantia nigra and a build-up of iron, particularly in the nigrosome-1 subregion. Telling it from non-neurodegenerative causes of parkinsonism can be difficult, and DAT-SPECT is used when the clinical picture is unclear.

Four radiologists first rated axial susceptibility map-weighted images without knowing the patients' symptoms or diagnoses. They then re-read the scans with AI-driven software built to classify and quantify nigrosome-1 integrity. The reference standard was the final clinical diagnosis, which incorporated the DAT-SPECT results.

Accuracy ranged from 73% to 83% across radiologists alone and from 85% to 91% with the software. The narrower range and higher kappa indicate the software also made the readers' calls more consistent.
sources:
- peer_reviewed | European Radiology Experimental | https://doi.org/10.1186/s41747-026-00832-w | 2026-11-14
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
72031e8f69b396bdb31ff491687666b7c5db101d3639099e09423735f59f8878
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-2942 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.