TRV-2026-2922Version 1 · Published

Saved · see the current record

Why this version exists

Certified into the record

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-2922
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-11-14T18:02:37.911394Z
status: published
lens: g_space
sector: health
headline: Efficacy of machine learning model and EU-TIRADS-PL reporting system in predicting thyroid malignancy risk: a comparison
dek: Thyroid nodules are common and mostly benign, but 5-15% are malignant. Increasing detection rates may lead to overdiagnosis and unnecessary fine-needle aspiration biopsies (FNAB). We aimed to develop a machine learning (ML) model for thyroid malignancy risk assessment using ultrasound, FNAB, laboratory data and to compare its performance with the EU-TIRADS-PL reporting system. This prospective study included 561 patients who underwent thyroidectomy based on preoperative ultrasound and FNAB results, including 261…
gain_title: In a prospective study of 561 thyroidectomy patients, a logistic regression model reached a test-set ROC AUC of 74% and correlated better with thyroid malignancy than the EU-TIRADS-PL ultrasound reporting system.
problem_title: (none)
trace_subject: (none)
gain_reading: In a prospective study of 561 thyroidectomy patients, a logistic regression model reached a test-set ROC AUC of 74% and correlated better with thyroid malignancy than the EU-TIRADS-PL ultrasound reporting system.
gain_evidence: The model achieved a test set ROC AUC of 74% and showed better correlation with thyroid malignancy than the EU-TIRADS-PL system.
problem_reading: (none)
problem_evidence: (none)
quick_read: A prospective study of 561 patients who had thyroidectomy built a machine learning model to estimate thyroid malignancy risk from ultrasound, fine-needle biopsy and laboratory data. The final logistic regression model reached a test-set ROC AUC of 74% and correlated better with malignancy than the EU-TIRADS-PL reporting system.

Thyroid nodules are common and mostly benign, but 5-15% are malignant, and rising detection may lead to overdiagnosis and unnecessary biopsies. A tool that sorts risk more accurately could help limit unneeded procedures, although the study did not measure that outcome.

The model flagged several predictors: microcalcifications, younger age, male sex and a larger anteroposterior dimension. A larger longitudinal dimension was linked to lower risk. A separate anteroposterior-to-longitudinal index reached an AUC of 68%.
limitation: Only patients who went on to thyroidectomy were included, and the model's test-set ROC AUC of 74% is modest.
tag: Evidence-backed gain
key_points: The study enrolled 561 patients who underwent thyroidectomy after preoperative ultrasound and fine-needle biopsy. | Of the nodules, 261 (46.5%) were malignant on histopathology. | Data were split 3:1 into training and test sets, and several ML algorithms were compared. | Logistic regression was chosen as the final model for its performance and interpretability. | The model's test-set ROC AUC was 74%. | Microcalcifications (p=0.002), younger age (p<0.001), male sex (p=0.001) and larger anteroposterior dimension (p=0.026) predicted malignancy. | A larger longitudinal dimension was associated with lower malignancy risk (p<0.001). | An anteroposterior-to-longitudinal dimension index had an ROC AUC of 68% (95% CI 62.0-71.0).
rundown: Researchers recruited 561 patients who underwent thyroidectomy based on preoperative ultrasound and fine-needle aspiration biopsy results. Malignancy was verified by histopathology and was present in 261 nodules (46.5%).

The team evaluated multiple machine learning algorithms using clinical, sonographic, cytological and biochemical variables, with data divided into training and test sets at a 3:1 ratio. Logistic regression was selected because it performed well and could be interpreted.

On the test set the model reached a ROC AUC of 74% and tracked malignancy better than EU-TIRADS-PL. The authors conclude it may improve risk assessment compared with systems based only on sonographic features.
sources:
- peer_reviewed | Endocrine Practice | https://doi.org/10.1016/j.eprac.2026.10.016 | 2026-11-13
prev: 0000000000000000000000000000000000000000000000000000000000000000
SHA-256 hash
99cb9f33a78769bea5351103dcaac5e8ae9e2ea4810c966b81d6360605dd1d37
Previous version’s hash
0000000000000000000000000000000000000000000000000000000000000000
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-2922 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.