Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-2913 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-14T12:02:09.016478Z status: published lens: g_space sector: health headline: OPXrayNet: a high-precision, explainable AI framework for transformative opportunistic osteoporosis screening utilizing multi-site X-ray imaging dek: Objective: This study aimed to develop and validate OPXrayNet, an automated deep-learning framework for opportunistic osteoporosis (OP) screening using multi-site skeletal X-ray images, to address the limitations of single-site analysis and poor interpretability in existing methods. Materials and methods: This retrospective, multicenter diagnostic study utilized 16,347 annotated X-ray images from 2186 patients. The reference standard was OP diagnosis based on DXA T-score (≤ -2.5). OPXrayNet integrated YOLOv8 for… gain_title: In a retrospective multicenter study of 2,186 patients, the OPXrayNet model detected osteoporosis on routine X-rays with 80.1% accuracy on an internal test set and an AUC of 0.844 on external validation, using DXA T-scores as the reference. problem_title: (none) trace_subject: (none) gain_reading: In a retrospective multicenter study of 2,186 patients, the OPXrayNet model detected osteoporosis on routine X-rays with 80.1% accuracy on an internal test set and an AUC of 0.844 on external validation, using DXA T-scores as the reference. gain_evidence: OPXrayNet achieved an accuracy of 80.1% | it attained an AUC of 0.844 (95% CI: 0.821-0.867) problem_reading: (none) problem_evidence: (none) quick_read: Researchers built OPXrayNet, a deep-learning system that screens for osteoporosis from routine skeletal X-rays taken at several body sites. In a retrospective study of 2,186 patients, it reached 80.1% accuracy on an internal test set of 3,892 and an AUC of 0.844 on an external validation set. Osteoporosis is normally diagnosed with a DXA scan, so reading ordinary X-rays already taken for other reasons could allow earlier detection in primary care without extra cost or radiation. The authors report that heatmaps suggest the model focuses on clinically important bone structures. The advantage over baseline models was modest: a 3.9% numerical difference on external validation, and the work is retrospective, so it has not shown any effect on patient care. limitation: The study was retrospective, and the observed advantage over other models was described only as a numerical difference of 3.9% on external validation. tag: Evidence-backed gain key_points: The retrospective multicenter study used 16,347 annotated X-ray images from 2,186 patients. | Participants had a mean age of 69.0 years and 72.3% were female. | The reference standard was osteoporosis diagnosed by DXA T-score of -2.5 or lower. | On the internal test set (n = 3,892), OPXrayNet reached 80.1% accuracy, above the baseline models. | On the external validation set, AUC was 0.844 (95% CI 0.821-0.867), a 3.9% numerical difference from other models. | Feature heatmaps suggest the model focuses on clinically important bone structures. rundown: OPXrayNet combines YOLOv8 for automatic detection of regions of interest, a spatial-frequency joint focusing architecture for feature enhancement, a feature pyramid network for multi-scale fusion and an expert-guided loss module. It was designed to overcome the limits of single-site analysis and poor interpretability in existing methods. Its performance was compared with other models, including DeepSeek-VL2 and DCNN, using statistical tests on internal and external validation sets. The baseline models' accuracy values were lower on the internal test. The authors conclude the tool shows promising performance for scalable use in primary care, because it uses routine X-rays and so needs no additional cost or radiation exposure. sources: - peer_reviewed | European Radiology | https://doi.org/10.1007/s00330-026-13023-3 | 2026-11-13 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- 70af8c6b9dcf203aaf0c1d5f339c5182a35ab409d3c6b0043ecf37aca28e2eb6
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-2913 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace