Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-2467 version: 1 kind: certified reason: Certified into the record timestamp: 2026-11-11T06:02:21.046528Z status: published lens: g_space sector: health headline: SECNet: Differentiable Mask-Driven Spatiotemporal Learning for Video-Based Spontaneous Echo Contrast Severity Detection dek: Spontaneous Echo Contrast (SEC), characterized by smoke-like dynamic echogenicity in trans esophageal echocardiography (TEE), serves as a critical imaging biomarker for assessing thromboembolic risk. However, current diagnostic approaches depend on manual interpretation or regression-based algorithms, which are labor-intensive, prone to inconsistency, and limited in generalizability. To address these challenges, we propose SECNet, an end-to-end deep learning framework for auto mated SEC detection in TEE videos.… gain_title: In a study of 1,106 annotated transesophageal echocardiography videos, the SECNet model graded spontaneous echo contrast severity with 93.7% accuracy, 3.1 to 23.3 percentage points above the compared methods. problem_title: (none) trace_subject: (none) gain_reading: In a study of 1,106 annotated transesophageal echocardiography videos, the SECNet model graded spontaneous echo contrast severity with 93.7% accuracy, 3.1 to 23.3 percentage points above the compared methods. gain_evidence: SECNet achieves 93.7% accuracy and a 90.0% F1-score | outper forming the compared methods by 3.1-23.3 percentage points in accuracy problem_reading: (none) problem_evidence: (none) quick_read: Researchers built SECNet, a deep learning system that detects and grades spontaneous echo contrast (SEC) in transesophageal echocardiography videos. Trained on 1,106 annotated videos, it reached 93.7% accuracy and a 90.0% F1-score, beating the compared methods by 3.1 to 23.3 percentage points in accuracy. SEC appears as smoke-like moving echoes on heart ultrasound and is used as an imaging marker of clotting risk. Current assessment relies on manual reading or regression-based algorithms, which the authors describe as labor-intensive, inconsistent and limited in how well they generalize. The authors say the tool supports standardized, reproducible assessment to assist clotting-risk evaluation in clinical workflows. limitation: tag: Evidence-backed gain key_points: SECNet was trained on a clinical dataset of 1,106 annotated transesophageal echocardiography videos. | It reached 93.7% accuracy and a 90.0% F1-score for SEC severity detection. | It beat the compared methods by 3.1 to 23.3 percentage points in accuracy. | One module segments the heart regions where SEC tends to appear and suppresses surrounding noise. | A second module captures how SEC moves over time and where it is distributed in the image. | A differentiable mask links the two modules so localization and classification are optimized together. | A further experiment on the EchoNet Dynamic dataset tested the architecture on a related echocardiographic video task. rundown: SECNet has two parts: a region-of-interest segmentation module that localizes cardiac structures prone to SEC while filtering out surrounding noise, and a spatiotemporal feature extraction module that captures both the motion and the spatial spread of the smoke-like pattern. The two modules are connected by a differentiable mask-guided bridge, which lets the localization and the severity classification be trained jointly rather than as separate steps. The authors also ran an auxiliary experiment on the public EchoNet Dynamic dataset, which they say shows the architecture can apply to a related echocardiographic video-analysis task. They say the approach could support standardized, reproducible SEC assessment in clinical workflows. sources: - peer_reviewed | IEEE Journal of Biomedical and Health Informatics | https://doi.org/10.1109/jbhi.2026.3751319 | 2026-11-06 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- ca1b02145c992f0c539417d3bdf2b8285bb46c71474f9e67217e8df21a45e884
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-2467 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace