lens: g_space
sector: health
headline: Heart failure and atrial fibrillation prediction from non-gated chest CT scans using AI-based cardiac chamber volumetry: an AI-CVD study within the multi-ethnic study of atherosclerosis (MESA)
dek: Background: We previously demonstrated that AI-derived cardiac chamber volumetry in ECG-gated CT scans predicts atrial fibrillation (AF) and heart failure (HF). Since most chest CTs are non-gated, and the American Heart Association recently highlighted their value for opportunistic cardiovascular risk assessment using AI-based coronary artery calcium scoring, we extended this concept to evaluate whether AI-derived chamber volumetry from non-gated CTs can reliably predict HF and AF.s.
Methods: We compared AI-deri…
gain_title: AI chamber volumetry on non-gated chest CT agreed closely with ECG-gated scans and predicted AF and HF about as well, supporting opportunistic risk screening.
problem_title: (none)
trace_subject: (none)
gain_reading: AI chamber volumetry on non-gated chest CT agreed closely with ECG-gated scans and predicted AF and HF about as well, supporting opportunistic risk screening.
gain_evidence: Non-gated scans demonstrated excellent overall agreement with ECG-gated scans | enabling opportunistic screening for HF and AF risk
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers tested whether an AI tool that measures heart chamber sizes could work on ordinary chest CT scans that are not synchronized to the heartbeat. They compared these measurements with those from ECG-gated scans in 2053 participants of the Multi-Ethnic Study of Atherosclerosis.

Because most chest CTs are non-gated, the finding suggests that existing scans could be reused to flag people at higher risk of heart failure or atrial fibrillation. The authors frame this cautiously, stating the approach may provide reliable measurement, and the report does not show clinical use or patient outcomes from screening itself.
limitation: 
tag: Evidence-backed gain
key_points: Agreement for detecting chamber enlargement was 98.8-99.2% (κ=0.76-0.84) between non-gated and gated scans. | Paired ECG-gated scans taken 2 minutes apart showed 98.6-98.9% agreement (κ=0.72-0.77) as a variability benchmark. | Age- and sex-adjusted C-index for left atrial volume was 0.75 versus 0.74 for non-gated versus gated. | Ventricular volume C-indices were 0.77 for both scan types, and the ventricular ratio was 0.74 for both.
rundown: The analysis used 2053 MESA Exam 5 participants to compare AI-derived chamber volumetry between non-gated and ECG-gated chest CTs, using absolute differences, intraclass correlation coefficients and Cohen's κ.

To set a benchmark for normal scan-to-scan variation, the team analyzed paired ECG-gated scans acquired 2 minutes apart in 5749 MESA Exam 1 participants.

Predictive performance for incident heart failure and atrial fibrillation was compared through cumulative incidence curves, adjusted C-indices and non-inferiority testing with a margin of 0.05. Quartile-stratified curves showed substantial overlap, and non-inferiority p-values were below 0.001.
sources:
- peer_reviewed | American Journal of Preventive Cardiology | https://doi.org/10.1016/j.ajpc.2026.101732 | 2026-07-05
prev: 0000000000000000000000000000000000000000000000000000000000000000
sha256
5168d21704b92d6926009270c2bf9a3a2f37a52eefa7d8bb25afe13264eedf16
previous
0000000000000000000000000000000000000000000000000000000000000000
Verify this record
How to verify without trusting this page

Fetch the canonical text of any version from /api/record/TRV-2026-1834 and hash it yourself — for example shasum -a 256 on the saved canonical field. The result must equal content_hash, and each version’s text ends with prev:followed by the prior version’s hash (version 1 chains to 64 zeros). If a single character of any version had been altered since certification, the chain would not reproduce.