TRV-2026-1739Version 1 · Certified

Written 2026-10-17 22:01:58 UTC · current record

Reason for this version

Certified into the record

Canonical text (the exact bytes fingerprinted)

TRUVACE RECORD VERSION
record: TRV-2026-1739
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-10-17T22:01:58.102918Z
status: published
lens: g_space
sector: health
headline: Machine Learning Models for Suspected Pulmonary Embolism in Emergency Department Patients: A Multicentre Diagnostic Study
dek: Pulmonary embolism (PE) is frequently suspected in emergency departments (EDs). Safely ruling out PE without additional testing could reduce imaging use and ED crowding. Machine learning (ML) may improve accuracy and efficiency.To evaluate ML models for ruling out PE without additional testing in ED patients with suspected PE, while maintaining a failure rate n = 2,400) and validation ( n = 2,638) datasets. ML models classified patients into low, intermediate, and high pre-test probability groups. In intermediat…
gain_title: A two-step ML algorithm ruled out pulmonary embolism with a failure rate below the 2% criterion and imaging use similar to the 4PEPS rule, and it did so without any testing for some patients.
problem_title: (none)
trace_subject: (none)
gain_reading: A two-step ML algorithm ruled out pulmonary embolism with a failure rate below the 2% criterion and imaging use similar to the 4PEPS rule, and it did so without any testing for some patients.
gain_evidence: achieving a failure rate of 1.44% (95% CI: 1.04-1.99) | This model ruled out PE without any testing in 9.7% of patients
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers built machine learning models to help emergency physicians decide which patients with suspected pulmonary embolism can be ruled out safely. The models sorted patients into low, intermediate and high pre-test probability groups. For intermediate-risk patients, a fixed D-dimer threshold or a second ML model refined the estimate. The models were assessed in a separate validation cohort of 2,638 patients.

The result matters because suspected pulmonary embolism is common in emergency departments, and avoiding unnecessary imaging could ease crowding. The ML approach performed about as well as existing rules rather than clearly better. The authors say prospective external validation is still needed before the approach can be trusted in practice.
limitation: 
tag: Evidence-backed gain
key_points: The best algorithm paired weighted ridge regression for pre-test probability with weighted random forest for post-test probability. | Failure rate, defined as the proportion of missed PE diagnoses, was 1.44% with a 95% CI of 1.04-1.99. | The Matthews correlation coefficient was 0.470 (95% CI: 0.440-0.500). | Estimated imaging proportion was 54.1%, against 52.9% for 4PEPS and 66.8% for PERC.
rundown: The study used development and validation datasets, with the validation set of 2,638 patients providing the primary failure-rate result. The prespecified safety target was a failure rate below 2%, and the upper confidence bound of the best model stayed under that value.

Comparison with clinical rules showed a trade-off between imaging and safety. The ML model's estimated imaging proportion was close to 4PEPS and well below PERC. It ruled out PE with no additional testing in 9.7% of patients.
sources:
- peer_reviewed | Thrombosis and Haemostasis | https://doi.org/10.1055/a-2939-4076 | 2026-10-08
prev: 0000000000000000000000000000000000000000000000000000000000000000
sha256
9ce90080ea74a2787c77449df4f23ae54604e547e49909672adcae1d857d62be
previous
0000000000000000000000000000000000000000000000000000000000000000
Verify this record
How to verify without trusting this page

Fetch the canonical text of any version from /api/record/TRV-2026-1739 and hash it yourself — for example shasum -a 256 on the saved canonical field. The result must equal content_hash, and each version’s text ends with prev:followed by the prior version’s hash (version 1 chains to 64 zeros). If a single character of any version had been altered since certification, the chain would not reproduce.