TRV-2026-1595Version 1 · Certified

Written 2026-10-16 18:13:12 UTC · current record

Reason for this version

Certified into the record

Canonical text (the exact bytes fingerprinted)

TRUVACE RECORD VERSION
record: TRV-2026-1595
version: 1
kind: certified
reason: Certified into the record
timestamp: 2026-10-16T18:13:12.670458Z
status: published
lens: p_space
sector: health
headline: Predictive performance of vital sign–based prediction models for in-hospital cardiac arrest: a systematic review and meta-analysis
dek: Abstract Background In-hospital cardiac arrest (IHCA) is a major patient-safety event often preceded by detectable clinical deterioration. Vital sign–based cardiac arrest prediction models have been developed to identify hospitalized patients at increased risk of IHCA, but their predictive performance has not been quantitatively synthesized across studies. Methods This PRISMA-based systematic review and meta-analysis was registered in PROSPERO. Ovid Embase, Ovid MEDLINE, and the Cochrane Central Register of Cont…
gain_title: (none)
problem_title: The evidence base is weak: half of included studies had high risk of bias, heterogeneity was substantial, and calibration, alert burden and clinical utility remain untested.
trace_subject: (none)
gain_reading: (none)
gain_evidence: (none)
problem_reading: The evidence base is weak: half of included studies had high risk of bias, heterogeneity was substantial, and calibration, alert burden and clinical utility remain untested.
problem_evidence: half of all included studies were judged to have a high overall risk of bias | heterogeneity was substantial
quick_read: A systematic review searched Embase, MEDLINE and CENTRAL and screened 10,645 records. Six studies met the criteria for models that use routine bedside vital signs to predict cardiac arrest in general ward patients, including CART, DEWS and DeepCARS.

The finding matters because in-hospital cardiac arrest is often preceded by detectable deterioration, so early warning tools could support patient safety. The pooled result is only exploratory, however, and it is unclear whether the models would work well in practice, with acceptable alert volumes, outside the studies that built them.
limitation: Only three studies contributed to the primary meta-analysis, heterogeneity was substantial, and half of the included studies had a high overall risk of bias, so the pooled AUROC is only an exploratory summary.
tag: Evidence-backed problem
key_points: Six studies published between 2012 and 2024 were included from 10,645 records identified. | Three studies reported cardiac arrest-specific AUROC estimates usable in the primary meta-analysis. | The exploratory pooled AUROC was 0.89 with a 95% CI of 0.88–0.91 and I² of 92%. | Risk of bias was low in two studies, high in three and unclear in one.
rundown: The review was PRISMA-based and registered in PROSPERO. It included peer-reviewed studies of vital sign–based models for hospitalized general ward patients. Models whose core predictors were laboratory values, imaging or other non-bedside variables were excluded.

AUROC was the primary performance measure, and AUPRC was extracted and summarized where studies reported it. Risk of bias was assessed with PROBAST + AI.

The authors call for standardized outcome definitions, external validation, and prospective evaluation of calibration, alert burden and clinical utility before broad clinical implementation.
sources:
- peer_reviewed | BMC Cardiovascular Disorders | https://doi.org/10.1186/s12872-026-06794-6 | 2026-10-15
prev: 0000000000000000000000000000000000000000000000000000000000000000
sha256
92b75a5b5a257134f99ac647dd612d673a37f5d651634cd52ab9b8cda52337da
previous
0000000000000000000000000000000000000000000000000000000000000000
Verify this record
How to verify without trusting this page

Fetch the canonical text of any version from /api/record/TRV-2026-1595 and hash it yourself — for example shasum -a 256 on the saved canonical field. The result must equal content_hash, and each version’s text ends with prev:followed by the prior version’s hash (version 1 chains to 64 zeros). If a single character of any version had been altered since certification, the chain would not reproduce.