TRV-2026-1284Version 3 · Revised

Saved · see the current record

Why this version exists

Editorial pass: sharper headline; gain/problem restated as concrete outcomes.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-1284
version: 3
kind: revised
reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
timestamp: 2026-11-04T09:50:16.977296Z
status: published
lens: p_space
sector: health
headline: Generative AI versus physicians in diagnostic radiology: a systematic review and meta-analysis
dek: Purpose Generative artificial intelligence (AI) models are increasingly evaluated for diagnostic tasks in radiology, yet accuracy, study designs, endpoints, and comparators vary widely. The purpose was to synthesize diagnostic accuracy of generative AI for radiology and compare performance with physicians. Materials and methods A systematic review and meta-analysis was prospectively registered in PROSPERO (CRD420251040000) and conducted in accordance with PRISMA-DTA guidance. Searches of Medline, Scopus, Web of…
gain_title: (none)
problem_title: Across 48 studies, generative AI was 13.0 percentage points less accurate than physicians at radiology diagnosis, with pooled accuracy of 42.9% on free-text tasks and 58.1% on choice tasks.
trace_subject: (none)
gain_reading: (none)
gain_evidence: (none)
problem_reading: Across 48 studies, generative AI was 13.0 percentage points less accurate than physicians at radiology diagnosis, with pooled accuracy of 42.9% on free-text tasks and 58.1% on choice tasks.
problem_evidence: Generative AI overall showed significantly lower accuracy than expert physicians | Generative AI remained less accurate than expert physicians on diagnostic tasks in radiology
quick_read: A systematic review and meta-analysis of 48 studies published through March 2025 synthesized diagnostic accuracy of generative AI in radiology and compared it to physician performance using multilevel random-effects meta-regression.

The finding matters because lower AI accuracy relative to experts raises safety concerns for clinical deployment, while the higher accuracy with text-only inputs suggests assistive, text-oriented use cases need further study but may be confounded by task difficulty and information content.
limitation: Observed differences in accuracy by input modality may be confounded by task difficulty and information content, and evaluations lacked standardization.
tag: Evidence-backed problem
key_points: Systematic review and meta-analysis of 48 studies from June 2018-March 2025 comparing generative AI to physicians on radiology diagnostic tasks. | Pooled generative AI accuracy was 42.9% for free-text tasks and 58.1% for choice tasks. | Multilevel random-effects meta-regression with study-clustered robust inference found text-only input outperformed image-only and text-and-image inputs. | Authors concluded standardized, transparently reported, adequately powered evaluations are warranted before clinical deployment.
rundown: The review was prospectively registered in PROSPERO and followed PRISMA-DTA guidance, searching Medline, Scopus, Web of Science, Cochrane Central, and medRxiv, with two reviewers screening and assessing bias with PROBAST+AI.

Analysis reported a difference of +13.0 percentage points for physicians minus AI (P = .038), and found image-only input was -25.9 percentage points lower than text-only (P = .001) and text-and-image was -10.6 points lower than text-only (P = .046).
sources:
- peer_reviewed | Japanese Journal of Radiology | https://doi.org/10.1007/s11604-026-02090-7 | 2026-10-03
prev: 5696754101ebcac4550101e016efc1ebf50024afea8f4db2e4e42eaafa561cc3
SHA-256 hash
76615f3c2ccd4c68f837d5916627a838e3c943391997cd37f3485c37d1d4d209
Previous version’s hash
5696754101ebcac4550101e016efc1ebf50024afea8f4db2e4e42eaafa561cc3
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-1284 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.