TRV-2026-1238Version 2 · Revised

Saved · see the current record

Why this version exists

Editorial pass: sharper headline; gain/problem restated as concrete outcomes.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-1238
version: 2
kind: revised
reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
timestamp: 2026-11-04T09:50:20.462587Z
status: published
lens: trace
sector: health
headline: Artificial Intelligence Triage of Urgent Versus Non-Urgent CT Brain Findings to Support Expedited Emergency Department Disposition: A Retrospective Validation Study
dek: Objective Evaluate the diagnostic accuracy of an artificial intelligence (AI) model for identifying urgent computed tomography brain (CTB) findings in consecutive emergency department (ED) patients and estimate the proportion eligible for expedited disposition. Methods We retrospectively analysed 3424 consecutive non-contrast CTB scans from adults presenting to a quaternary ED in 2024. The AI model (Harrison Enterprise CTB) classified each scan as "urgent" or "non-urgent." The reference standard was the index co…
gain_title: In a retrospective test on 3424 emergency head CT scans, the AI's non-urgent calls were right 98.3% of the time, and 64% of encounters were potentially eligible for faster disposition.
problem_title: The AI initially missed 37 urgent scans (85.4% sensitivity); a single unblinded re-review reclassified 24 as non-urgent, leaving 13 small or subtle findings, and specificity was only 69.1%.
trace_subject: triage of urgent versus non-urgent non-contrast CT brain findings in emergency department patients using Harrison Enterprise CTB
gain_reading: In a retrospective test on 3424 emergency head CT scans, the AI's non-urgent calls were right 98.3% of the time, and 64% of encounters were potentially eligible for faster disposition.
gain_evidence: An estimated 64.0% of encounters were true negatives potentially eligible for expedited disposition | None of the 13 cases required urgent intervention during the index ED presentation
problem_reading: The AI initially missed 37 urgent scans (85.4% sensitivity); a single unblinded re-review reclassified 24 as non-urgent, leaving 13 small or subtle findings, and specificity was only 69.1%.
problem_evidence: Of 3424 scans, 253 (7.4%) had urgent findings on the reference standard | Of 37 false negatives, independent adjudication reclassified 24 as non-urgent
quick_read: Researchers retrospectively tested an AI model that classifies non-contrast CT brain scans as urgent or non-urgent on 3424 consecutive adult scans from a quaternary emergency department in 2024. Against consultant radiologist reports as reference, the model achieved 85.4% sensitivity, 69.1% specificity and 98.3% NPV, with 64% of encounters identified as true negatives potentially eligible for expedited disposition.

The high NPV supports a safety rationale for a prospective trial to incorporate AI triage into ED workflows to speed disposition, but initial false negatives and reliance on a single-center retrospective design with report-based reference and unblinded post hoc re-adjudication leave uncertainty about real-world safety and generalizability.
limitation: Retrospective single-center design using radiologist report alone as reference, and post hoc false-negative re-adjudication by a single unblinded assessor with access to medical record, limits generalizability before prospective trial.
tag: Dual reading
key_points: Study analyzed 3424 consecutive non-contrast CTB scans from adults presenting to a quaternary ED in 2024. | Reference standard was the index consultant radiologist report alone, classified by two emergency physicians with blinded radiologist tiebreak, all blinded to AI output. | Initial sensitivity was 85.4% (95% CI 80.0%-89.0%) and specificity 69.1% (95% CI 67.0%-71.0%) with 253 (7.4%) urgent findings. | Post hoc re-adjudication of 37 false negatives by a single unblinded assessor reclassified 24 as non-urgent, raising sensitivity to 94.3% and NPV to 99.4%.
rundown: The study evaluated Harrison Enterprise CTB on 3424 consecutive adult non-contrast CT brain scans from a quaternary ED in 2024, comparing AI classification of urgent versus non-urgent against consultant radiologist reports classified by emergency physicians blinded to AI output.

Initial results showed 253 urgent cases, sensitivity 85.4% and NPV 98.3%, with 64% true negatives potentially eligible for expedited disposition; post hoc unblinded re-adjudication of 37 false negatives reclassified 24 as non-urgent, leaving 13 small or subtle findings that did not require urgent intervention during the index presentation.
sources:
- peer_reviewed | Emergency Medicine Australasia | https://doi.org/10.1111/1742-6723.70353 | 2026-10-01
prev: 653a20785412fa3d9d5f989698a901aadb3def4c4467351286fc05dbe558429b
SHA-256 hash
1eda0966c2ba8e57f9ec177908e59cab59237f9f29990383ae1e6c967e51a742
Previous version’s hash
653a20785412fa3d9d5f989698a901aadb3def4c4467351286fc05dbe558429b
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-1238 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.