Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-1237 version: 2 kind: revised reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes. timestamp: 2026-11-04T09:50:19.892542Z status: published lens: g_space sector: health headline: Comparative evaluation of VoxelMorpand conventional deformable image registration algorithms for thoracic 4D-CT in radiotherapy dek: Background Deformable image registration (DIR) is essential for thoracic four-dimensional computed tomography (4D-CT)-based radiotherapy applications. Recently, deep learning-based DIR methods such as VoxelMorph have been proposed; however, their performance relative to clinically used DIR algorithms remains unclear. Purpose This study aimed to evaluate the DIR accuracy of VoxelMorph for thoracic 4D-CT and to compare it with conventional clinical and research-oriented DIR methods. Materials and methods Thoracic… gain_title: On 10 test lung cancer patients, VoxelMorph cut median CT-value error from 67.56 to 36.83 HU, close to ANACONDA (36.18) and Demons (37.39), with a median lung overlap of 0.98 and shorter processing time. problem_title: (none) trace_subject: (none) gain_reading: On 10 test lung cancer patients, VoxelMorph cut median CT-value error from 67.56 to 36.83 HU, close to ANACONDA (36.18) and Demons (37.39), with a median lung overlap of 0.98 and shorter processing time. gain_evidence: median DSC increased from 0.91 to 0.95 for modified Demons, 0.97 for Demons and ANACONDA, and 0.98 for VoxelMorph | median MAE decreased from 67.56 HU before DIR to 52.32 HU with modified Demons, 37.39 HU with Demons, 36.18 HU with ANACONDA, and 36.83 HU with VoxelMorph | VoxelMorph demonstrated DIR performance comparable to that of clinically used algorithms for thoracic 4D-CT, with high overlap accuracy, relatively low inter-case variability and shorter processing times under the evaluated implementation conditions problem_reading: (none) problem_evidence: (none) quick_read: Researchers retrospectively evaluated VoxelMorph deep learning deformable registration on thoracic 4D-CT from 64 lung cancer patients, training on 50 cases and testing on 10 against Demons, modified Demons, and ANACONDA using end-inhalation to end-exhalation registration. By the October 2026 publication date, the test results showed VoxelMorph achieving comparable accuracy to clinical tools with high lung overlap and reduced processing time in this implementation, but the authors noted that broader standardized validation is still needed to support routine radiotherapy use. limitation: Findings are limited to a small test set of 10 cases from a single retrospective cohort of 64 patients and to the specific implementation conditions, requiring further validation under standardized conditions before routine clinical use. tag: Evidence-backed gain key_points: Retrospective analysis used thoracic 4D-CT from 64 lung cancer patients, with end-inhalation and end-exhalation phases for registration. | VoxelMorph was trained on 50 cases, validated on 4, and tested on 10, compared against Demons (SimpleITK), modified Demons (Eclipse), and ANACONDA (RayStation). | Accuracy metrics were MAE of CT values within body region, and DSC and HD95 within lung label, with median HD95 of 2.5 mm for VoxelMorph versus 2.0 mm for ANACONDA. rundown: The study used end-inhalation and end-exhalation images from 64 lung cancer patients, splitting 50 for training VoxelMorph, 4 for validation, and 10 for testing against three conventional methods. On the 10-case test set, median MAE fell from 67.56 HU pre-registration to 36.83 HU with VoxelMorph, compared to 36.18 HU for ANACONDA and 37.39 HU for Demons, while median DSC rose to 0.98 and median HD95 was 2.5 mm. sources: - peer_reviewed | Journal of Applied Clinical Medical Physics | https://doi.org/10.1002/acm2.70816 | 2026-10-01 prev: 8976fe971dc267d3b3c52dcd5bad0c785aae7880b2e7f98c6370f1525b993e0f
- SHA-256 hash
- 47db6eb8dae04fec86e6a632958700ca21c4102bc2f3601858cac2a6db0c61bf
- Previous version’s hash
- 8976fe971dc267d3b3c52dcd5bad0c785aae7880b2e7f98c6370f1525b993e0f
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-1237 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace