TRV-2026-0850Version 2 · Revised

Saved · see the current record

Why this version exists

Editorial pass: sharper headline; gain/problem restated as concrete outcomes.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0850
version: 2
kind: revised
reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
timestamp: 2026-11-04T09:50:42.249719Z
status: published
lens: g_space
sector: health
headline: An interpretable multi-instance learning method for accurate differentiation of malignant and benign laryngeal lesions in laryngoscopy
dek: Background Laryngeal cancer is a significant global health issue with high mortality, and early diagnosis is critical for survival. Developing accurate diagnostic models for laryngoscopy can reduce potential repeated biopsies and lessen the patient burden, representing an urgent clinical need. However, existing artificial intelligence models often function as black boxes and are trained on single, pre-selected images, which does not reflect the clinical workflow where multiple images are assessed. Methods We con…
gain_title: In a retrospective study of 611 patients, the IMIL-Net AI model separated malignant from benign laryngeal lesions in laryngoscopy images with 91.5% accuracy, 87.6% sensitivity and 94.5% specificity.
problem_title: (none)
trace_subject: (none)
gain_reading: In a retrospective study of 611 patients, the IMIL-Net AI model separated malignant from benign laryngeal lesions in laryngoscopy images with 91.5% accuracy, 87.6% sensitivity and 94.5% specificity.
gain_evidence: (none)
problem_reading: (none)
problem_evidence: (none)
quick_read: Background Laryngeal cancer is a significant global health issue with high mortality, and early diagnosis is critical for survival. Developing accurate diagnostic models for laryngoscopy can reduce potential repeated biopsies and lessen the patient burden, representing an urgent clinical need.

However, existing artificial intelligence models often function as black boxes and are trained on single, pre-selected images, which does not reflect the clinical workflow where multiple images are assessed. Methods We conducted a retrospective study on 611 patients who underwent white light endoscopy (WLE) examinations.
limitation: 
tag: Evidence-backed gain
key_points: Background Laryngeal cancer is a significant global health issue with high mortality, and early diagnosis is critical for survival. | Developing accurate diagnostic models for laryngoscopy can reduce potential repeated biopsies and lessen the patient burden, representing an urgent clinical need. | However, existing artificial intelligence models often function as black boxes and are trained on single, pre-selected images, which does not reflect the clinical workflow where multiple images are assessed.
rundown: Background Laryngeal cancer is a significant global health issue with high mortality, and early diagnosis is critical for survival. Developing accurate diagnostic models for laryngoscopy can reduce potential repeated biopsies and lessen the patient burden, representing an urgent clinical need.

However, existing artificial intelligence models often function as black boxes and are trained on single, pre-selected images, which does not reflect the clinical workflow where multiple images are assessed. Methods We conducted a retrospective study on 611 patients who underwent white light endoscopy (WLE) examinations.
sources:
- peer_reviewed | European Archives of Oto-Rhino-Laryngology | https://doi.org/10.1007/s00405-026-10540-1 | 2026-08-20
prev: 3bba2e7366bbec92604c617b312c7f1fd7c87e40cb2dc70c83ffeb8b9bb144d6
SHA-256 hash
08178a9003aa9c3ea160cb010a7d1eb8e6a7a4fdabe1493155a1aebd471f8556
Previous version’s hash
3bba2e7366bbec92604c617b312c7f1fd7c87e40cb2dc70c83ffeb8b9bb144d6
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0850 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.