TRV-2026-0848Version 2 · Revised

Saved · see the current record

Why this version exists

Editorial pass: sharper headline; gain/problem restated as concrete outcomes.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0848
version: 2
kind: revised
reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
timestamp: 2026-11-04T09:50:42.462826Z
status: published
lens: g_space
sector: health
headline: Radiological assessment of pulmonary vascularity in congenital heart disease: standardized clinician assessment versus deep learning-based prediction
dek: Background Assessment of pulmonary vascularity on chest radiographs (CXRs) in congenital heart disease (CHD) is limited by subjectivity, and existing criteria lack sufficient validation. Artificial intelligence-based deep learning model (DLM) analysis may improve accuracy. We developed and validated structured criteria and a DLM to evaluate pulmonary vascularity and compared it with conventional clinical interpretation. Methods A total of 400 deidentified CXRs from CHD patients with Fick-derived pulmonary-to-sys…
gain_title: On 400 chest X-rays from patients with congenital heart disease, a deep learning model estimated lung blood flow in close agreement with catheter measurements (correlation 0.782) and outperformed clinicians' structured assessment.
problem_title: (none)
trace_subject: (none)
gain_reading: On 400 chest X-rays from patients with congenital heart disease, a deep learning model estimated lung blood flow in close agreement with catheter measurements (correlation 0.782) and outperformed clinicians' structured assessment.
gain_evidence: (none)
problem_reading: (none)
problem_evidence: (none)
quick_read: Background Assessment of pulmonary vascularity on chest radiographs (CXRs) in congenital heart disease (CHD) is limited by subjectivity, and existing criteria lack sufficient validation. Artificial intelligence-based deep learning model (DLM) analysis may improve accuracy.

Results Intraclass correlation between Fick- and DLM-derived Qp:Qs was 0.782 (P 1.5: 90% specificity, 98% sensitivity, area under the receiver operating characteristic curve [AUROC] 98%; predicting Qp:Qs Conclusion Deep learning-based analysis of CXRs enables accurate evaluation of pulmonary vascularity and outperforms structured assessment by clinicians.
limitation: 
tag: Evidence-backed gain
key_points: Background Assessment of pulmonary vascularity on chest radiographs (CXRs) in congenital heart disease (CHD) is limited by subjectivity, and existing criteria lack sufficient validation. | Artificial intelligence-based deep learning model (DLM) analysis may improve accuracy. | We developed and validated structured criteria and a DLM to evaluate pulmonary vascularity and compared it with conventional clinical interpretation.
rundown: Background Assessment of pulmonary vascularity on chest radiographs (CXRs) in congenital heart disease (CHD) is limited by subjectivity, and existing criteria lack sufficient validation. Artificial intelligence-based deep learning model (DLM) analysis may improve accuracy.

We developed and validated structured criteria and a DLM to evaluate pulmonary vascularity and compared it with conventional clinical interpretation. Methods A total of 400 deidentified CXRs from CHD patients with Fick-derived pulmonary-to-systemic flow ratio (Qp:Qs) were evaluated by three experts and three trainees in pediatric cardiology and radiology using nine prespecified criteria.
sources:
- peer_reviewed | Journal of Cardiovascular Imaging | https://doi.org/10.1186/s44348-026-00084-7 | 2026-08-21
prev: 6cf66d9fbee45ac804ff5dfc5a55d40db1c0920f7f6b1b0625edae8d5175ca01
SHA-256 hash
d0e9bc13597f16f22e5c0fa20410b5aa36ca718d153c7bf563397551e9eb1c85
Previous version’s hash
6cf66d9fbee45ac804ff5dfc5a55d40db1c0920f7f6b1b0625edae8d5175ca01
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0848 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.