TRV-2026-0798Version 3 · Revised

Saved · see the current record

Why this version exists

Voice pass: plainer wording and study attribution; no facts or figures changed.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0798
version: 3
kind: revised
reason: Voice pass: plainer wording and study attribution; no facts or figures changed.
timestamp: 2026-11-05T11:20:21.760675Z
status: published
lens: g_space
sector: health
headline: Validation of artificial intelligence-assisted CBCT analysis for predicting inferior alveolar nerve proximity to impacted mandibular third molars: a diagnostic accuracy study
dek: This study aimed to evaluate the diagnostic accuracy of an artificial intelligence (AI)-assisted cone-beam computed tomography (CBCT) analysis system for predicting the spatial proximity of the inferior alveolar nerve (IAN) to impacted mandibular third molars (M3M), using expert radiologist assessment as the reference standard. A retrospective diagnostic accuracy study was conducted on an internal institutional cohort of 312 patients (mean age 28.21 ± 6.62 years; January 2021-December 2024). A deep learning syst…
gain_title: In a single-center retrospective test on 486 sites, an AI system matched two senior radiologists' readings of jaw-nerve proximity to wisdom teeth 90.1% of the time, in 4.75 seconds versus 189.12 seconds for experts.
problem_title: (none)
trace_subject: (none)
gain_reading: In a single-center retrospective test on 486 sites, an AI system matched two senior radiologists' readings of jaw-nerve proximity to wisdom teeth 90.1% of the time, in 4.75 seconds versus 189.12 seconds for experts.
gain_evidence: The AI system achieved an overall accuracy of 90.1% (438/486; 95% CI: 87.1-92.5%)
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers retrospectively tested a deep learning system that automatically segments the inferior alveolar nerve canal and impacted mandibular third molars on CBCT and classifies their spatial relationship. On an independent hold-out set of 486 sites, the system reached 90.1% overall accuracy and 0.925 weighted AUC against two senior radiologists, with processing time of 4.75 seconds versus 189.12 seconds for experts.

The result matters because IAN injury risk assessment is a key preoperative step for wisdom tooth removal, and automated CBCT analysis could support faster decision-making if validated. Uncertainty remains because the reference was radiographic interpretation, not intraoperative nerve exposure or postoperative neurosensory outcomes, and the data were single-center retrospective, requiring prospective multicenter study.
limitation: Reference standard was radiographic expert assessment rather than intraoperative findings, and authors state prospective multicenter validation with surgical outcomes is needed before clinical deployment.
tag: Evidence-backed gain
key_points: Retrospective diagnostic accuracy study on 312 patients (Jan 2021-Dec 2024) with independent hold-out test set of 486 M3 sites from 283 patients. | Deep learning system automatically segmented IAN canal and M3M and classified relationship as no contact (>2 mm), proximity (0-2 mm), and contact/overlap. | Reference standard was two senior oral and maxillofacial radiologists; metrics included sensitivity, specificity, PPV, NPV, AUC, Cohen's kappa with Wilson and bootstrap CIs. | Reported weighted AUC 0.925, Cohen's ba 0.851, mean DSC 0.90 for IAN canal and 0.93 for M3M, and Bland-Altman mean difference 0.06 mm.
rundown: The study used an internal institutional cohort of 312 patients (mean age 28.21 7 6.62 years) and evaluated performance on 486 M3 sites. The system segmented the IAN canal and impacted M3M and assigned three proximity categories, with per-category sensitivity 88.2% to 91.2% and specificity 92.8% to 97.4%.

Subgroup analysis found highest accuracy for mesioangular (93.1%) and horizontal (91.6%) impaction. Segmentation quality was reported as mean DSC 0.90 7 0.04 for IAN canal and 0.93 7 0.03 for M3M, with Bland-Altman mean difference 0.06 mm (95% LoA: -0.63 to 0.75 mm).
sources:
- peer_reviewed | BMC Oral Health | https://doi.org/10.1186/s12903-026-08690-z | 2026-08-15
prev: e6946ce4c6a3f70d8319bbefb0a6e7b3c45f4944c72ce84bca6eb3baa5e51cad
SHA-256 hash
08d68fed73c3cc4d41d23e323f165f2200fe0ceefa0f19c92d66ef01117256a6
Previous version’s hash
e6946ce4c6a3f70d8319bbefb0a6e7b3c45f4944c72ce84bca6eb3baa5e51cad
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0798 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.