This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0775
version: 4
kind: revised
reason: Voice pass: plainer wording and study attribution; no facts or figures changed.
timestamp: 2026-11-05T11:20:23.497138Z
status: published
lens: g_space
sector: health
headline: Noise-aware dynamic convolution for improved generalizability of retinal disease diagnosis using optical coherence tomography images
dek: Significance Optical coherence tomography (OCT) is widely used for the diagnosis of retinal diseases. However, deep learning models trained on a single dataset often degrade when deployed across scanners and clinical sites due to device-dependent speckle variability and acquisition differences, limiting their reliability in real-world screening. Aim We aim to develop a lightweight deep learning framework that leverages speckle characteristics in OCT images to improve cross-scanner generalizability for retinal di…
gain_title: On over 105,000 eye scans from three groups, tested on scanners it was not trained on, the NA-DyCNN model reached up to 92.87% accuracy and beat other lightweight models.
problem_title: (none)
trace_subject: (none)
gain_reading: On over 105,000 eye scans from three groups, tested on scanners it was not trained on, the NA-DyCNN model reached up to 92.87% accuracy and beat other lightweight models.
gain_evidence: deep learning models trained on a single dataset often degrade when deployed across scanners and clinical sites due to device-dependent speckle variability and acquisition differences, limiting their reliability in real-world screening
problem_reading: (none)
problem_evidence: (none)
quick_read: Researchers developed NA-DyCNN, a lightweight noise-aware dynamic convolutional network for OCT-based retinal disease classification that explicitly models post-acquisition speckle variability during training to work more reliably across scanners.

By publication on 2026-08-12, the model had been evaluated on over 105,000 B-scans from three heterogeneous cohorts in zero-shot transfer, reaching up to 92.87% accuracy and 0.53 ms latency, suggesting potential for more reliable AI-assisted screening across devices, though real-world clinical deployment and broader scanner diversity remain to be validated.
limitation: 
tag: Evidence-backed gain
key_points: Proposed NA-DyCNN minimizes expected classification risk over stochastic multiplicative speckle perturbations and regularizes dynamic routing for scanner-invariant kernel mixtures. | Evaluation used over 105,000 B-scans from three heterogeneous OCT cohorts under strict zero-shot cross-dataset transfer across four scenarios. | Model maintained high efficiency with only 0.4 M parameters and an inference latency of 0.53 ms per B-scan on an NVIDIA GB10 GPU.
rundown: OCT is widely used for retinal disease diagnosis, but models trained on one dataset degrade across devices due to speckle variability and acquisition differences.

Authors developed NA-DyCNN, a lightweight noise-aware dynamic CNN that models multiplicative speckle perturbations during training and regularizes dynamic routing to produce scanner-invariant kernel mixtures.

Tested on over 105,000 B-scans from three heterogeneous cohorts in four zero-shot transfer scenarios, NA-DyCNN outperformed lightweight baselines and maintained 0.4M parameters with 0.53 ms per B-scan latency on an NVIDIA GB10 GPU.
sources:
- peer_reviewed | Journal of Biomedical Optics | https://doi.org/10.1117/1.jbo.31.8.086006 | 2026-08-12
prev: b06cd9256663e1fd40c6ce8a7c020671ed2f9d384ad249c0fbb4195211022b5d
SHA-256 hash
ced4f3e63fe148480695aea32377cb686a9c3b5955a458c5520b8e221124601c
Previous version’s hash
b06cd9256663e1fd40c6ce8a7c020671ed2f9d384ad249c0fbb4195211022b5d
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0775 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.