Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-0759 version: 2 kind: revised reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes. timestamp: 2026-11-04T09:50:47.749772Z status: published lens: g_space sector: health headline: CURL-AID: Automated Echocardiographic Motion Analysis for Quantitative Assessment of Posterior Systolic Curling dek: Objective Posterior systolic curling (PSC) is a morphofunctional abnormality of the posterior mitral annulus associated with malignant ventricular arrhythmias and sudden cardiac death. Current diagnosis is qualitative and operator-dependent, limiting reproducibility, objectivity and standardization. This study introduces CURL-AID (Curling Ultrasound-based Recognition and Labeling-Automated Intelligence-driven Diagnosis), a fully automated echocardiographic framework for PSC detection through quantitative analysi… gain_title: In 100 patients at one center, an automated ultrasound tool detected posterior systolic curling, a valve motion abnormality, with 82% accuracy (AUC 0.865) against clinicians' visual assessment, tested only internally. problem_title: (none) trace_subject: (none) gain_reading: In 100 patients at one center, an automated ultrasound tool detected posterior systolic curling, a valve motion abnormality, with 82% accuracy (AUC 0.865) against clinicians' visual assessment, tested only internally. gain_evidence: CURL-AID provides a quantitative and reproducible assessment of PSC and may support automated identification of a phenotype associated with arrhythmic risk. | Automated segmentation achieved a median Dice of 0.88 and Jaccard index of 0.79 for the posterior wall problem_reading: (none) problem_evidence: (none) quick_read: On 2026-08-12, a peer-reviewed study described CURL-AID, a fully automated framework that segments the posterior mitral annulus and left ventricular wall on parasternal long-axis echocardiograms, tracks tissue motion, and classifies posterior systolic curling using nine kinematic features in 100 retrospectively analyzed patients. Posterior systolic curling is linked to arrhythmic risk but currently diagnosed qualitatively, so a reproducible quantitative tool could improve standardization and risk stratification; uncertainty remains because performance was measured only with internal nested cross-validation on a single view and single-center retrospective cohort without prospective or external validation. limitation: Findings are based on 100 retrospectively collected parasternal long-axis echocardiograms with internal nested cross-validation and no reported external validation or prospective testing. tag: Evidence-backed gain key_points: Study analyzed 100 patients (40 PSC, 60 noPSC) classified by three independent clinicians based on dynamic visual assessment. | Pipeline combined convolutional neural network segmentation, point-wise tissue tracking, and nine selected kinematic features reflecting increased tangential and radial displacement. | Best model was linear support vector machine evaluated with repeated, stratified nested cross-validation. rundown: Researchers developed CURL-AID to replace qualitative operator-dependent visual assessment of posterior systolic curling with automated segmentation of the posterior wall and annulus and point-wise motion tracking from parasternal long-axis views. From 100 cases, bootstrapped Elastic Net and Sequential Backward Selection identified nine motion descriptors showing increased displacement and irregular systolic acceleration in PSC, yielding median Dice 0.88 for wall segmentation and centroid errors of 2.0 mm validation and 1.6 mm test for annulus localization. sources: - peer_reviewed | Ultrasound in Medicine & Biology | https://doi.org/10.1016/j.ultrasmedbio.2026.07.018 | 2026-08-12 prev: e2ee821fcb3eedaa4399718545855f00606fed39349965bf330b9d8662293172
- SHA-256 hash
- 100b5ff291f88d2b853e08258002d520d5dcc0632aae41e79127230ad31216b1
- Previous version’s hash
- e2ee821fcb3eedaa4399718545855f00606fed39349965bf330b9d8662293172
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-0759 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace