Voice pass: plainer wording and study attribution; no facts or figures changed.
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-0753 version: 3 kind: revised reason: Voice pass: plainer wording and study attribution; no facts or figures changed. timestamp: 2026-11-05T11:20:25.156909Z status: published lens: trace sector: climate headline: Effect of Deep Learning Training Policy on Greenhouse Gas Emissions and Carbon Efficiency for Chest Radiograph Classification dek: Purpose Environmental sustainability is an emerging priority in radiology, yet the impact of deep learning training policies on greenhouse gas emissions remains poorly characterized. This study quantified the effect of training policy on carbon dioxide equivalent (CO 2 eq) emissions and model performance for chest radiograph classification. Methods Anteroposterior chest radiographs (128 907 training, 24 570 validation, 8282 test) were used to train 3 ImageNet-pretrained convolutional neural networks (ResNet-50,… gain_title: In tests of three chest X-ray AI models, stopping training early kept accuracy (macro-AUC about 0.793-0.800) while cutting total emissions 31% to 38% versus fixed 20-epoch training. problem_title: In tests of three chest X-ray AI models, finding the best one took a full run of 30.8 to 49.4 g CO2 eq, though the model actually used accounted for only 6.2 to 7.9 g. trace_subject: greenhouse gas emissions and carbon efficiency of chest radiograph classification training under different stopping policies gain_reading: In tests of three chest X-ray AI models, stopping training early kept accuracy (macro-AUC about 0.793-0.800) while cutting total emissions 31% to 38% versus fixed 20-epoch training. gain_evidence: Prospective early stopping had macro-AUCs equivalent to the retrospective optimum (0.793-0.800), with 31% to 38% lower total emissions (21.1-30.9 vs 30.8-49.4 g CO 2 eq) | improved carbon efficiency by up to 76% versus fixed 20-epoch training | 57% to 76% higher carbon efficiency (25.9-37.6 vs 14.7-24.0 AUC/kg CO 2 eq) compared to fixed-epoch training problem_reading: In tests of three chest X-ray AI models, finding the best one took a full run of 30.8 to 49.4 g CO2 eq, though the model actually used accounted for only 6.2 to 7.9 g. problem_evidence: 78% to 84% of training emissions accruing after the deployed checkpoint | Up to 84% of total training emissions accrued after the optimal checkpoint quick_read: In a study published August 12, 2026, researchers quantified CO2eq emissions for training ResNet-50, DenseNet-121 and EfficientNet-B0 on 128,907 chest radiographs for 20 epochs. They found validation loss minima at median epochs 2 to 4, meaning most emissions occurred after the best checkpoint, and compared retrospective selection, prospective early stopping, and fixed-epoch training on AUC and energy use. The findings matter because radiology AI development carries a measurable carbon cost that can be reduced without sacrificing diagnostic performance. Prospective early stopping preserved macro-AUC around 0.793-0.800 while lowering total emissions by 31% to 38% and improving carbon efficiency by 57% to 76% versus fixed training, though savings depend on comparator and the analysis is limited to three architectures and a single chest X-ray task. limitation: tag: Dual reading key_points: Study used 128,907 training, 24,570 validation, and 8,282 test anteroposterior chest radiographs to train ResNet-50, DenseNet-121, and EfficientNet-B0 for 20 epochs. | Validation loss minimum occurred at median epoch 2 for ResNet-50 and DenseNet-121 and epoch 4 for EfficientNet-B0. | At retrospective optimum, models generated 6.2 to 7.9 g CO2 eq (37-46 Wh) at deployed checkpoint but required full run of 30.8 to 49.4 g CO2 eq (181-291 Wh). rundown: Researchers trained three ImageNet-pretrained CNNs on anteroposterior chest radiographs and compared three policies: retrospective optimal checkpoint selection at validation loss minimum, prospective early stopping with patience 10, and fixed 20-epoch training. They tracked per-epoch CO2eq, energy in Wh, macro-averaged AUC, and carbon efficiency. Retrospective optimum macro-AUCs ranged from 0.793 to 0.800 with only 6.2 to 7.9 g CO2eq at the deployed checkpoint, yet the full run needed to find it emitted 30.8 to 49.4 g. Prospective early stopping matched retrospective performance while cutting total emissions to 21.1-30.9 g and increasing efficiency to 25.9-37.6 AUC/kg CO2eq. sources: - peer_reviewed | Canadian Association of Radiologists Journal | https://doi.org/10.1177/08465371261475319 | 2026-08-12 prev: ab9ad5d7e34c9416e31b1b42f123024bd0206d01855aea518e1144239d42e99f
- SHA-256 hash
- b00f5ed57445f4372f0f9001e844e248bc116929fe071331b2fa37af092c7077
- Previous version’s hash
- ab9ad5d7e34c9416e31b1b42f123024bd0206d01855aea518e1144239d42e99f
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-0753 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace