Certified into the record
The exact text we saved
This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.
TRUVACE RECORD VERSION record: TRV-2026-0753 version: 1 kind: certified reason: Certified into the record timestamp: 2026-08-14T06:21:38.686399Z status: published lens: trace sector: climate headline: Effect of Deep Learning Training Policy on Greenhouse Gas Emissions and Carbon Efficiency for Chest Radiograph Classification dek: Purpose Environmental sustainability is an emerging priority in radiology, yet the impact of deep learning training policies on greenhouse gas emissions remains poorly characterized. This study quantified the effect of training policy on carbon dioxide equivalent (CO 2 eq) emissions and model performance for chest radiograph classification. Methods Anteroposterior chest radiographs (128 907 training, 24 570 validation, 8282 test) were used to train 3 ImageNet-pretrained convolutional neural networks (ResNet-50,… gain_title: Prospective early stopping with patience 10 preserved chest radiograph classification performance while lowering total training emissions by up to 38% and raising carbon efficiency by up to 76% compared to fixed 20-epoch training. problem_title: Fixed 20-epoch training without checkpoint selection wasted most compute, with 78% to 84% of total emissions occurring after the optimal checkpoint had already been reached. trace_subject: greenhouse gas emissions and carbon efficiency of chest radiograph classification training under different stopping policies gain_reading: Prospective early stopping with patience 10 preserved chest radiograph classification performance while lowering total training emissions by up to 38% and raising carbon efficiency by up to 76% compared to fixed 20-epoch training. gain_evidence: Prospective early stopping had macro-AUCs equivalent to the retrospective optimum (0.793-0.800), with 31% to 38% lower total emissions (21.1-30.9 vs 30.8-49.4 g CO 2 eq) | improved carbon efficiency by up to 76% versus fixed 20-epoch training | 57% to 76% higher carbon efficiency (25.9-37.6 vs 14.7-24.0 AUC/kg CO 2 eq) compared to fixed-epoch training problem_reading: Fixed 20-epoch training without checkpoint selection wasted most compute, with 78% to 84% of total emissions occurring after the optimal checkpoint had already been reached. problem_evidence: 78% to 84% of training emissions accruing after the deployed checkpoint | Up to 84% of total training emissions accrued after the optimal checkpoint quick_read: In a study published August 12, 2026, researchers quantified CO2eq emissions for training ResNet-50, DenseNet-121 and EfficientNet-B0 on 128,907 chest radiographs for 20 epochs. They found validation loss minima at median epochs 2 to 4, meaning most emissions occurred after the best checkpoint, and compared retrospective selection, prospective early stopping, and fixed-epoch training on AUC and energy use. The findings matter because radiology AI development carries a measurable carbon cost that can be reduced without sacrificing diagnostic performance. Prospective early stopping preserved macro-AUC around 0.793-0.800 while lowering total emissions by 31% to 38% and improving carbon efficiency by 57% to 76% versus fixed training, though savings depend on comparator and the analysis is limited to three architectures and a single chest X-ray task. limitation: tag: Dual reading key_points: Study used 128,907 training, 24,570 validation, and 8,282 test anteroposterior chest radiographs to train ResNet-50, DenseNet-121, and EfficientNet-B0 for 20 epochs. | Validation loss minimum occurred at median epoch 2 for ResNet-50 and DenseNet-121 and epoch 4 for EfficientNet-B0. | At retrospective optimum, models generated 6.2 to 7.9 g CO2 eq (37-46 Wh) at deployed checkpoint but required full run of 30.8 to 49.4 g CO2 eq (181-291 Wh). rundown: Researchers trained three ImageNet-pretrained CNNs on anteroposterior chest radiographs and compared three policies: retrospective optimal checkpoint selection at validation loss minimum, prospective early stopping with patience 10, and fixed 20-epoch training. They tracked per-epoch CO2eq, energy in Wh, macro-averaged AUC, and carbon efficiency. Retrospective optimum macro-AUCs ranged from 0.793 to 0.800 with only 6.2 to 7.9 g CO2eq at the deployed checkpoint, yet the full run needed to find it emitted 30.8 to 49.4 g. Prospective early stopping matched retrospective performance while cutting total emissions to 21.1-30.9 g and increasing efficiency to 25.9-37.6 AUC/kg CO2eq. sources: - peer_reviewed | Canadian Association of Radiologists Journal | https://doi.org/10.1177/08465371261475319 | 2026-08-12 prev: 0000000000000000000000000000000000000000000000000000000000000000
- SHA-256 hash
- b1a75daf9e65ad7a1788195b4d47dd798e081cd25629d532f2f5e3582bc06ef9
- Previous version’s hash
- 0000000000000000000000000000000000000000000000000000000000000000
How to check it yourself, without trusting this page
Download any version from /api/record/TRV-2026-0753 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.
ace