TRV-2026-0679Version 2 · Revised

Saved · see the current record

Why this version exists

Editorial pass: sharper headline; gain/problem restated as concrete outcomes.

The exact text we saved

This is the version exactly as it was saved, character for character. The SHA-256 hash below is a 64-character code worked out from that text. Run the same text through SHA-256 and you get the same code; change a single letter and the code comes out completely different. Each version also stores the previous version’s hash, which chains them together so no version can be swapped out quietly.

TRUVACE RECORD VERSION
record: TRV-2026-0679
version: 2
kind: revised
reason: Editorial pass: sharper headline; gain/problem restated as concrete outcomes.
timestamp: 2026-11-04T09:50:52.698565Z
status: published
lens: g_space
sector: health
headline: The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures: A Systematic Review and Meta-analysis
dek: Background Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated chol…
gain_title: Pooled across five studies covering 675 lesions, AI-assisted cholangioscopy diagnosed indeterminate and malignant biliary strictures with 95% sensitivity and 88% specificity.
problem_title: (none)
trace_subject: (none)
gain_reading: Pooled across five studies covering 675 lesions, AI-assisted cholangioscopy diagnosed indeterminate and malignant biliary strictures with 95% sensitivity and 88% specificity.
gain_evidence: pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94) | Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures
problem_reading: (none)
problem_evidence: (none)
quick_read: By August 2026, researchers published a systematic review and meta-analysis of AI combined with digital cholangioscopy for indeterminate and malignant biliary strictures. The analysis pooled five studies totaling 675 lesions and 2,685,674 images, finding pooled sensitivity of 95%, specificity of 88%, and SROC accuracy of 97% for AI-assisted diagnosis.

Accurate diagnosis of biliary strictures is clinically important because current ERCP and cholangioscopic sampling remain suboptimal, and improved computer-vision support could reduce missed malignancies. The findings remain preliminary given the small number of studies and lack of reported prospective clinical outcomes, implementation data, or harms.
limitation: Evidence base is limited to five studies with 675 lesions, indicating early-stage evaluation rather than broad clinical validation.
tag: Evidence-backed gain
key_points: Systematic review and meta-analysis included 5 studies covering 675 lesions and 2,685,674 cholangioscopic images. | Four of five studies used deep learning with a convoluted neural network processing 30 to 60 frames per second. | Bivariate model was used to compute pooled sensitivity, specificity, likelihood ratio, diagnostic odds ratio, and SROC curve. | Sensitivity analysis of CNN-only studies (538 patients) showed 95% sensitivity, 88% specificity, and 97% SROC accuracy.
rundown: The review searched per PRISMA and MOOSE guidelines and applied Cochrane Diagnostic Test Accuracy methodology with a bivariate model to pool results across studies.

Most systems analyzed were CNN-based deep learning models operating at 30 to 60 frames per second, evaluated on a combined dataset of over 2.6 million cholangioscopic images from 675 lesions.
sources:
- peer_reviewed | Journal of Clinical Gastroenterology | https://doi.org/10.1097/mcg.0000000000002148 | 2026-08-06
prev: c243d62976ad879b241ce0a872e9edb7ade7cb35d923d1b5a0aabc0e153a4200
SHA-256 hash
90e610b7ae2902c3d9c08ffb48e3be4ecabd1d4139f641217d8541cd18f642ee
Previous version’s hash
c243d62976ad879b241ce0a872e9edb7ade7cb35d923d1b5a0aabc0e153a4200
Check this record hasn’t been altered
How to check it yourself, without trusting this page

Download any version from /api/record/TRV-2026-0679 and hash its canonical field yourself, for example with shasum -a 256. You should get its content_hash. Each version’s text also ends with prev:and the hash of the version before it (version 1 points to 64 zeros). If anyone had changed a single character of any version after it was saved, those hashes wouldn’t line up.