TRV-2026-0266Version 1 · Certified
Reason for this version
Certified into the record
Canonical text (the exact bytes fingerprinted)
TRUVACE RECORD VERSION record: TRV-2026-0266 version: 1 kind: certified reason: Certified into the record timestamp: 2026-07-19T00:58:43.785932Z status: published lens: p_space sector: health headline: The VISION-AI Trial: protocol for a pragmatic randomized controlled non-inferiority trial comparing artificial intelligence-guided colonoscopy to pancolonic chromoendoscopy for neoplasia detection in adults with colorectal inflammatory bowel disease dek: Current guidelines recommend pancolonic chromoendoscopy (pCE) over white light endoscopy (WLE) alone for colorectal neoplasia (CRN) detection in individuals with inflammatory bowel diseases (IBD). However, these techniques are poorly adopted due to technical and logistical limitations. Artificial intelligence-based computer-aided detection (CADe) is a promising new technology integrated into modern endoscopy platforms that has been shown to increase CRN detection in the non-IBD population. We aim to compare CADe… gain_title: (none) problem_title: Current AI detection systems are not specifically trained for IBD-related lesions, limiting effectiveness for colorectal neoplasia detection in inflammatory bowel disease. trace_subject: (none) gain_reading: (none) gain_evidence: (none) problem_reading: Current AI detection systems are not specifically trained for IBD-related lesions, limiting effectiveness for colorectal neoplasia detection in inflammatory bowel disease. problem_evidence: current AI systems are not specifically trained for IBD-related lesions, limiting effectiveness quick_read: On July 17, 2026, BMC Gastroenterology published the VISION-AI protocol for a pragmatic multicenter non-inferiority randomized trial comparing artificial intelligence-based computer-aided detection guided colonoscopy to pancolonic chromoendoscopy for visible colorectal neoplasia detection in adults with longstanding inflammatory bowel disease. The design targets 752 participants with a 15% anticipated neoplasia rate and 7.5% non-inferiority margin, and reports that enrollment started in April 2026 with 19 participants recruited by June 8, 2026. The trial matters because individuals with inflammatory bowel disease face elevated colorectal cancer risk and guideline-recommended chromoendoscopy is poorly adopted, creating a need for more implementable detection strategies. Whether AI trained largely on non-IBD lesions can achieve non-inferior detection in inflamed and scarred mucosa remains unproven, and no comparative effectiveness results are available while recruitment continues. limitation: Current AI systems are not specifically trained for IBD-related lesions, which may limit effectiveness in this population, and trial has not yet generated efficacy results. tag: Evidence-backed problem key_points: Pragmatic multicenter parallel-group open-label non-inferiority RCT comparing CADe-guided colonoscopy to pancolonic chromoendoscopy (virtual or dye spray). | Eligible: adults >=18 with longstanding >=8 years IBD or any duration with primary sclerosing cholangitis involving >=1/3 colorectum in clinical remission undergoing surveillance. | Primary outcome is visible colorectal neoplasia detected at colonoscopy; secondary includes mean number of CRN, high-risk CRN, procedural time, adverse events, endoscopist acceptance. | Sample size 752 participants to demonstrate non-inferiority with 7.5% margin at one-sided alpha 2.5% and 80% power assuming 15% CRN rate in both groups. | As of June 8, 2026, 19 of target 752 participants recruited; enrollment began April 2026 and study remains in active recruitment phase. rundown: The protocol describes central randomization by permuted blocks stratified by endoscopist, with primary analysis restricted to high-quality colonoscopy defined as adequate preparation, minimal inflammation, and complete intubation, and both per-protocol and intention-to-treat analyses planned. The trial is registered as ACTRN12626000102370 and follows SPIRIT 2025 guidelines, noting that pancolonic chromoendoscopy is recommended over white light endoscopy alone but is poorly adopted due to technical and logistical limitations. sources: - peer_reviewed | BMC Gastroenterology | https://doi.org/10.1186/s12876-026-05046-3 | 2026-07-17 prev: 0000000000000000000000000000000000000000000000000000000000000000
- sha256
- 2971f7029a11473892c404512698092576073cff828621b224e65de4ee48069b
- previous
- 0000000000000000000000000000000000000000000000000000000000000000
Verify this record
How to verify without trusting this page
Fetch the canonical text of any version from /api/record/TRV-2026-0266 and hash it yourself — for example shasum -a 256 on the saved canonical field. The result must equal content_hash, and each version’s text ends with prev:followed by the prior version’s hash (version 1 chains to 64 zeros). If a single character of any version had been altered since certification, the chain would not reproduce.
ace