82% accuracy: AI tool flagged a heart valve motion problem in a 100-patient study

Study title: CURL-AID: Automated Echocardiographic Motion Analysis for Quantitative Assessment of Posterior Systolic Curling

Evidence type
Observational study
Sample
n = 100
Sources
1 sourcePeer-reviewed
Published
1 min read

Study title: CURL-AID: Automated Echocardiographic Motion Analysis for Quantitative Assessment of Posterior Systolic Curling

On 2026-08-12, a peer-reviewed study described CURL-AID, a fully automated framework that segments the posterior mitral annulus and left ventricular wall on parasternal long-axis echocardiograms, tracks tissue motion, and classifies posterior systolic curling using nine kinematic features in 100 retrospectively analyzed patients.

Read the study abstract

Objective Posterior systolic curling (PSC) is a morphofunctional abnormality of the posterior mitral annulus associated with malignant ventricular arrhythmias and sudden cardiac death. Current diagnosis is qualitative and operator-dependent, limiting reproducibility, objectivity and standardization. This study introduces CURL-AID (Curling Ultrasound-based Recognition and Labeling-Automated Intelligence-driven Diagnosis), a fully automated echocardiographic framework for PSC detection through quantitative analysi…

CURL-AID: Automated Echocardiographic Motion Analysis for Quantitative Assessment of Posterior Systolic Curling
2D Echocardiogram showing Mitral Regurgitation in PLAX view - Navi Mumbai by Goleisureintl. CC BY 4.0 · Wikimedia Commons

The gain

In a study of 100 patients at one center, an automated ultrasound tool detected posterior systolic curling, a valve motion abnormality, with 82% accuracy (AUC 0.865) against clinicians' visual assessment, tested only internally.

In brief

Posterior systolic curling is linked to arrhythmic risk but currently diagnosed qualitatively, so a reproducible quantitative tool could improve standardization and risk stratification; uncertainty remains because performance was measured only with internal nested cross-validation on a single view and single-center retrospective cohort without prospective or external validation.

Main points

  1. Study analyzed 100 patients (40 PSC, 60 noPSC) classified by three independent clinicians based on dynamic visual assessment.
  2. Pipeline combined convolutional neural network segmentation, point-wise tissue tracking, and nine selected kinematic features reflecting increased tangential and radial displacement.
  3. Best model was linear support vector machine evaluated with repeated, stratified nested cross-validation.

The full story

Researchers developed CURL-AID to replace qualitative operator-dependent visual assessment of posterior systolic curling with automated segmentation of the posterior wall and annulus and point-wise motion tracking from parasternal long-axis views.

From 100 cases, bootstrapped Elastic Net and Sequential Backward Selection identified nine motion descriptors showing increased displacement and irregular systolic acceleration in PSC, yielding median Dice 0.88 for wall segmentation and centroid errors of 2.0 mm validation and 1.6 mm test for annulus localization.

Sources

1 on file
  1. Ultrasound in Medicine & Biologydoi:10.1016/j.ultrasmedbio.2026.07.018
    Peer-reviewed2026-08-12

Talk it over

Three questions to start on, two more if you have time
CURL-AID reached 82% accuracy against the visual assessment of three clinicians in 100 patients at one center. If the clinicians themselves sometimes disagreed, what would that accuracy figure mean, and what check would settle whether the tool is right?

Start with a question

82% accuracy: AI tool flagged a heart valve motion problem in a 100-patient studyhttps://truvace.com/item/curl-aid-automated-echocardiographic-motion-analysis-for-quantitative-assessment

  1. CURL-AID reached 82% accuracy against the visual assessment of three clinicians in 100 patients at one center. If the clinicians themselves sometimes disagreed, what would that accuracy figure mean, and what check would settle whether the tool is right?

    Answer in the thread
  2. The tool was tested only with internal nested cross-validation on parasternal long-axis views. What result from outside that setting would change your mind about whether CURL-AID is ready for use?

    Answer in the thread
  3. Posterior systolic curling is currently judged by eye. If you were one of the three clinicians who classified the 40 PSC and 60 noPSC patients, how would you use an automated score alongside your own call?

    Answer in the thread
If you have more time
  • Look up how often clinicians disagree when judging posterior systolic curling by eye. How would that disagreement change what 82% accuracy against their assessment means?

    Answer in the thread
  • What would a prospective study of CURL-AID need to include, such as other centers or other echocardiogram views, to settle whether it helps with arrhythmic risk?

    Answer in the thread

What readers say